Cardin Elettronica SL Serie Manual Del Usuario página 57

Centrales multifuncionales para automatizaciones autoprogramables
Ocultar thumbs Ver también para SL Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 178
4c) Limited opening
• Press PROG/OK to scroll between the available choices:
- Selection 1 = 1/3 travel distance of gate 1; Selection 2 = 1/2 travel distance of gate 1
- Selection 3 = 2/3 travel distance of gate 1; Selection 4 = complete travel distance of gate 1
• Press the arrow button
next parameter.
Limited opening allowing pedestrian access (TAL button). The limited opening command can also be imparted
remotely using a radio control button.
4d) Distance from the closing travel limit
• Press PROG/OK to scroll between the available choices:
- 0 steps; 1 step; 2 steps (default setting); 3 steps; 4 steps; 5 steps; 6 steps; 7 steps; 8 steps; 9 steps
• Press the arrow button
choice and move to the next parameter.
Setting the distance from the closing travel limit (encoder count). Once the opening and closing mechanical
travel limits have been detected the programmer will apply this correction in order to prevent the sliding gate
from colliding into the mechanical travel limits after every work cycle.
4e) Distance from the opening travel limit
• Press PROG/OK to scroll between the available choices:
- 0 steps; 1 step; 2 steps (default setting); 3 steps; 4 steps; 5 steps; 6 steps; 7 steps; 8 steps; 9 steps
• Press the arrow button
choice and move to the next parameter.
Setting the distance from the opening travel limit (encoder count). Once the opening and closing mechanical
travel limits have been detected the programmer will apply this correction in order to prevent the sliding gate
from colliding into the mechanical travel limits after every work cycle.
to confirm. The programmer will save the choice and move to the
to confirm the choice eg. 2 steps; The programmer will save the
to confirm the choice eg. 3 steps. The programmer will save the
57
4c) Limited opening
MOTOR SELECTION
BL3924MCB
CURRENT SENSOR
LEVEL 1
LIMITED
OPENING
SELECTION 1
4d) Distance from close
CURRENT SENSOR
LEVEL 2
LIMITED
OPENING
3 METERS
DIST. FROM CLOSE
2 STEPS
4e) Distance from open
LIMITED
OPENING
3 METERS
DIST. FROM CLOSE
4 STEPS
DIST.
FROM OPEN
3 STEPS
Tabla de contenido
loading

Este manual también es adecuado para:

Bl serieHl serieSli serieBli serie

Tabla de contenido