4i) Open brake room
• Press PROG/OK to scroll between the available choices:
- Setting 0 = disabled (default setting); Setting 1 = minimum distance
Setting 2 = medium distance; Setting 3 = maximum distance
• Press the arrow button
choice and move to the next parameter.
Setting the braking room towards the end of the opening stage.
4m) Open brake speed
• Press PROG/OK to scroll between the available choices:
- Setting 1 = low speed; Setting 2 = medium speed; Setting 3 = high speed
• Press the arrow button
choice and move to the next parameter.
Setting the braking speed during opening. The default parameter is '1' but it only tales effect if parameter 4i
'open braking room' is set to 1, 2 or 3.
4n) Final braking speed
• Press PROG/OK to scroll between the available choices:
- Setting 0 = disabled; Setting 1 = low speed; Setting 2 = medium speed; Setting 3 = medium high
speed; Setting 4 = high speed; Setting 5 = maximum speed
• Press the arrow button
choice and move to the next parameter.
The five settings are valid only for inside motors; for SLX series motors Setting 3 = maximum speed
to confirm the choice eg. Setting 2. The programmer will save the
to confirm the choice eg. Setting 3. The programmer will save the
to confirm the choice eg. Setting 3. The programmer will save the
.
59
4i) Open brake room
CLOSE BRAKE ROOM
SETTING 2
CLOSE BRAKE SPEED
SETTING 3
OPEN BRAKE ROOM
SETTING 2
4m) Open brake speed
CLOSE BRAKE SPEED
SETTING 3
OPEN BRAKE ROOM
SETTING 2
OPEN BRAKE SPEED
SETTING 3
4n) Final braking speed
DIST. FROM CLOSE
4 STEPS
DIST.
FROM OPEN
4 STEPS
FINAL
BRAKING
SETTING 1