WARNING: Never connect the 230 voltage output of the equipment to a
building or house (not even during a power outage). The return of the main
network would clash with the generator's voltage and cause serious damage to the
equipment or even a fire.
WARNING: Do not connect the generators in parallel, both will be damaged
and will be a fire hazard.
NOTE: Do not connect an extension to the exhaust.
NOTE: When an extension cable is required, ensure to use a good quality
rubber cable with a proper section, ask your electrician.
NOTE: Devices that use an engine such as compressors, water pumps, saws,
compressors, etc. require up to 3 times more power for startup. For example, a
500 W water pump would need a 1500 W generator for startup. Verify that charges
upon connection do not exceed the maximum power of the group according to this
indication. If you have any doubts about the equipment to be connected send the
equipment information to

6.1 Use of the bases of 230V AC

NOTE: Check that no devices are plugged into the generator; unplug
everything before starting the engine.
Start the engine following the steps indicated in this manual.
Once started check that the 2 thermal protection circuit breakers are "ON" (up) as
shown in the graph below.
Now, you can connect the devices to the 230V bases of the generator.
56
THERMAL PROTECTOR