Westinghouse WH3250 Manual Del Propietário página 35

Ocultar thumbs Ver también para WH3250:
Idiomas disponibles

Idiomas disponibles

Clean All Alternator Cooling
Air Inlets and Exhaust
Ports - Make sure the cooling air inlets and exhaust
ports of the alternator are free of any debris and
obstructions. Use a vacuum cleaner to remove dirt and
debris stuck in the cooling air inlets and exhaust ports
(see Figure 46 and Figure 47).
Figure 46 - Alternator Cooling Air Inlet and Outlet Port
LONG-TERM
STORAGE
Never store a generator
with fuel in the
tank indoors or in a poorly ventilated
area where the fumes can come in
contact
with an ignition source such
as a: 1) pilot light of a stove, water
heater, clothes dryer or any other gas
appliance;
or 2) spark from an electric
appliance.
Gasoline stored for as little as 60 days can go bad,
causing gum, varnish and corrosive buildup in fuel
lines, fuel passages and the engine. This corrosive
buildup restricts the flow of fuel, preventing an engine
from starting after a prolonged storage period.
Proper care should be taken to prepare the generator for
any long-term storage.
Storage
Procedure
for 1 - 3 Months
1.
Clean the generator as outlined in Cleaning the
Generator on page 34.
2.
Add a gasoline fuel stabilizer to the fuel tank. Follow
the recommended
procedure of the fuel stabilizer
manufacturer for correct amount of stabilizer to add.
Storage
Procedure
for Greater Than 3
Figure 47- Alternator Cooling Air Inlet and Outlet Port
General Cleaning
of the Generator
- Use a damp rag
to clean all remaining surfaces.
,
2.
3.
,
5.
,
,
8.
Clean the generator as outlined in Cleaning the
Generator on page 34.
Drain all gasoline from the fuel tank as best as
possible.
With the fuel shutoff valve open, start the engine
and allow the generator to run until all the remaining
gasoline in the fuel lines and carburetor is
consumed and the engine shuts off.
Close the fuel shutoff valve.
Change the oil (see Changing Engine Oil on page
30).
Remove the spark plug (see Spark Plug Maintenance
on page 32) and place about 1 tablespoon of oil
in the spark plug opening. While placing a clean rag
over the spark plug opening, slowly pull the recoil
handle to allow the engine to turn over several times.
This will distribute the oil and protect the cylinder wall
from corroding during storage.
Replace the spark plug (see Spark Plug
Maintenance on page 32).
Move the generator to a clean, dry place for storage.
35
loading