8 MAINTENANCE AND LUBRICATION
Check and tighten the engine fan belt and replace the belt, clamps and hoses (see maintenance chart).
Have your Jacobsen Dealer check the cooling system if you need to add coolant more than one time a month or
you add more than a litre of coolant at a time.
Check the engine coolant level
(a)
The level of coolant in a cold expansion tank must be
between the indicators.
(b)
If you need to fill the tank, remove the plastic cap and fill with
the correct antifreeze mixture (see section 8.1).
(c)
Replace the plastic cap ensure feed tube is still attached.
How to change coolant
(a)
To drain coolant, remove the bottom hose (A) from the
radiator. Drain the engine coolant into a container.
(b)
Replace the bottom hose (A) on to the radiator. Make sure all
the hose clips are tight.
(c)
Fill the cooling system with the correct antifreeze mixture,
(Section 8.1.) Fill system through the radiator cap.
(d)
The level of coolant in a cold expansion tank must be
between the indicators.
(e)
Run the engine for approximately 5 minutes or until the
thermostat opens.
(f)
Check the level of coolant in expansion tank. Fill the tank if more coolant is needed.
The antifreeze can damage your skin. Use gloves when you use antifreeze.
Discard antifreeze in accordance with local Authority recommendations.
en-68
!
If antifreeze touches your skin, clean the area immediately.
!
CAUTION
CAUTION