Fig. 11: Fastening the valve system with retaining brackets, example
12.2 Pneumatic installation conditions
Fig. 12 shows an example configuration for an AV valve system with AES bus cou-
pler.
37
38
39
AES-
D-BC-
XXX
UA
P
Fig. 12: Example configuration
37
AES bus coupler
39
Pneumatic supply plate
41
AV-EP pressure regulator valve for
pressure zone control
43
End plate
12.2.1 AV-EP for single pressure control
Single pressure regulators can be positioned at any point between the AES bus
coupler (37) and end plate (43).
If you pressurize or exhaust more than six valves at once, e.g. one single pressure
control and six directional valves, observe the following:
1. With a pneumatic supply plate (39), make sure that an additional supply or ex-
haust air connection is available.
2. Position additional pneumatic supply plates spaced evenly in the valve system
or near valves with the highest compressed air consumptions.
3. Do not place the pneumatic supply plates directly adjacent to one another.
12.2.2 AV-EP for pressure zone control
Place the AV-EP pressure regulator directly adjacent to the directional valves
u
(42) to be supplied. The AV-EP pressure regulator is located on the side facing
the AES bus coupler (37) (see Fig. 12, pressure zone PZ).
The maximum overall flow of all actuated directional valves is limited by the max-
imum nominal flow of the pressure regulator. The maximum nominal flow can be
found on the pages for individual components in our online catalog
(www.aventics.com/pneumatics-catalog).
To achieve the maximum flow of the AV-EP pressure regulator, we recommend a
pneumatic supply plate (39) upstream of the pressure regulator (see example
configuration in Fig. 12).
AVENTICS™ AV-EP | R414007537-BAL-001-AB | English
SW3
M
= 2,5 Nm
D
40
39
41
AV-EP
AV-EP
A
P
PZ
38
Transition plate
40
AV-EP pressure regulator for single
pressure control
42
Valve
PZ
Pressure zone
12.2.3 Single pressure control and pressure zone control in one valve
system
If you use both control types in one valve system:
Position the single pressure control (40) between the AES bus coupler (37)
u
and the pressure zone control (41), see example configuration in Fig. 12.
12.3 Electrical installation conditions
Valve system layout for multipole connection
In valve systems with 25-pin D-Sub plug, the first AV-EP pressure regu-
lator may only be placed after the second valve, and in valve systems
with 44-pin D-Sub plug, after the fourth valve.
The rules for converting your valve system with fieldbus connection
depend on the fieldbus protocol used. You can find information on
converting your valve system in the bus coupler system descriptions
on CD R412018133.
12.3.1 Number of electrical components
In an AV valve system, you can operate a maximum of 32 electrical components.
Some configured components have multiple functions and therefore count as
multiple electrical components.
Table 13: Number of electrical components
42
43
Configured component
Valve driver boards, 2x
Valve driver boards, 3x
Valve driver boards, 4x
Pressure regulators
Electrical supply plate
The series AES bus coupler can process 128 bits for controlling valves and 128
bits for controlling AV-EP pressure regulators.
Each AV-EP pressure regulator has a data length of 16 bits. With 128 bits, eight
AV-EP pressure regulators are possible.
The online configurator assists you in correctly designing your valve system. The
conditions stated above will also be considered in this context.
13 Integrating AV-EP into an AV valve system
The extension of an AV multipole valve system with AV-EP pressure
regulators for multipole connection is not possible. AV multipole valve
systems can, however, be configured with AV-EP pressure regulators
for multipole connection.
Danger of injury if assembled under pressure or voltage!
Assembling when under pressure or electrical voltage can lead to injuries and
damage to the product or system components. Danger of injury from electric
shocks and sudden pressure drops.
1. Make sure the relevant system part is not under pressure or voltage before
performing the following tasks:
- Assembling the product
- Removing or connecting plugs
- Disassembling the system
- Exchanging individual components
2. Protect the system against being restarted.
Risk of burns due to hot surfaces!
Touching the surfaces of the AV-EP during operation could cause burns. The
temperature on uncoated metal can exceed 64 °C and on polymers can exceed
85 °C.
1. Let the device cool off before working on it.
2. Do not touch the device during operation.
Number of electrical components
1
1
1
3
1
CAUTION
CAUTION
32