Emerson AVENTICS AV-EP Serie Instrucciones De Servicio página 27

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 73
48
49
50
51
49
50
51
Table 5: Meaning of the LEDs on the AV-EP pressure regulators for fieldbus con-
nection
Designation
Color
State
UL (49)
Green
Off
Illumi-
nated
UA (50)
Green
Flashes
Illumi-
nated
DIAG (51)
Green/
Off
Red
Green
Flashes
Illumi-
nated
Red
Illumi-
nated
8.2 LEDs in devices for multipole connection
47
48
49 50 51
49 50 51
Table 6: Meaning of the LEDs on the AV-EP pressure regulators for multipole con-
nection
Designation
Color
State
UL (49)
Green
Off
Illumi-
nated
UA (50)
Green
Flashes
Illumi-
nated
DIAG (51)
Green/
Off
Red
Green
Flashes
AVENTICS™ AV-EP | R414007537-BAL-001-AB | English
On devices with display, the LEDs (48) are in-
tegrated in the display housing; the LEDs on
the rear are inactive.
The LEDs on the AV-EP pressure regulator
show the messages listed in Table 5
ing of the LEDs on the AV-EP pressure regula-
tors for fieldbus
connection.
u Before commissioning and during opera-
tion, regularly check AV-EP functions by
reading the LEDs.
Meaning
No electronics power supply present
Electronics power supply present
Valve power supply below the bottom tolerance limit
of 19.2 V DC (24 V DC -20 %)
Valve power supply above the bottom tolerance limit
of 19.2 V DC (24 V DC -20 %)
Set point = 0 bar
The actual value is outside of the tolerance.
The actual value is within the tolerance.
Safety cut-off active or parameter error (see chap-
ter 15 g 15. Troubleshooting)
The LEDs serve to monitor voltage and diag-
nosis.
On devices without display, the LEDs (47) are
on the rear.
On devices with display, the LEDs (48) are in-
tegrated in the display housing; the LEDs on
the rear are inactive.
The LEDs on the AV-EP pressure regulator
show the messages listed in Table
ing of the LEDs on the AV-EP pressure regula-
tors for multipole
connection.
u Before commissioning and during opera-
tion, regularly check AV-EP functions by
reading the LEDs.
Meaning
No supply present
Power present
Power supply below the bottom tolerance limit of
19.2 V DC (24 V DC -20 %)
Power supply above the bottom tolerance limit of
19.2 V DC (24 V DC -20 %)
Set point = 0 bar
The actual value is outside of the tolerance.
Designation
Color
Red
8.3 Display
g  Mean-
52
54
55
56
Fig. 9: Display areas
54
Level display/area for texts:
• Menu level
• Edit level
56
Area for symbols/icons:
• Button input option (arrow)
• Horizontal bar graph
58
"Lock" symbol
8.4 Navigation with buttons
g  Mean-
Table 7: The AV-EP pressure regulator is operated via three buttons.
53
Table 8: Button functions
Button
Meaning
/(ESC)
Menu level: Briefly pressing the
menu item within the same menu level.
Pressing and holding the
level higher (Escape).
Edit level: The
State
Meaning
Illumi-
The actual value is within the tolerance.
nated
Illumi-
Safety cut-off active
(see chapter g 15. Trou-
nated
bleshooting)
Depending on the configuration, your AV-EP
features a display (52) to read out the set val-
ues and parameters on-site.
55
Area for actual values:
• Values
Units
57
"User adjustment active" symbol
With the buttons (53) below the display, you
can set the parameters
displays
in this chapter).
In AV-EP pressure regulators for fieldbus con-
nection, the parameter settings from the
menu items
g 8.6.7 Control
g 8.6.8 Pressure range
the fieldbus.
button takes you to the previous
button for at least 1 s takes you to one menu
button displays the previous or next lower value.
57
58
(g 8.6 Settings and
and
are overwritten by
27
loading

Este manual también es adecuado para:

Aventics av03-epAventics av05-ep