Faults

7
Faults
Mechanical seal
NOTICE
It is normal for a few drops of water to escape from the
mechanical seal from time to time. This is especially true during
the break-in period.
Depending on the water quality and number of operating hours,
the mechanical seal can begin to leak.
If water leaks constantly, have the mechanical seal replaced
by a qualified technician.
NOTICE
We recommend first informing the swimming pool contractor if
there are irregularities.
Plain bearing
NOTICE
Magnetically coupled pumps have a plain bearing. When the plain
bearing is run dry it creates warmth and both the plain bearing
and pump parts are damaged.
Ensure that the pump/unit is always filled with the pump
media. This also applies to checking the rotation direction.
Never allow the pump to run against closed spacers.
7.1

Overview

Problem: Pump is switched off by the built-in or external overload
switch.
Possible cause
Overload.
Problem: Pump seizes.
Possible cause
Mechanical seal is stuck.
24 EN
Solution
Check the pump.. See
point 7.1.1 on page 25
Solution
Turn the motor shaft. See
point 6.1.2 on page 22
Clean pump.
06|2021