Ballast Blades Inspection; Replacement Of Blades; Blade Sizes; Important - battioni Pagani BALLAST 3500 Manual De Instrucciones De Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 132
user and maintenance
instruction manual BALLAST series
Figure 11

11.3.3 REPLACEMENT OF BLADES

1. Check whether there is sufficient space at the back of the rotary blades vacuum pump
to operate smoothly, otherwise the
rotary blades vacuum pump must be previously dismantled from its support;
2. Remove the back
3. Extract the blades from the rotor;
4. Clean the Rotary blades vacuum pump.
5. Replace the blades and the gasket and the seals of the rear flange;
6. Re-fit the back of the rotary blades vacuum pump
7. Use only Battioni Pagani
Request the rotary blades vacuum pump servicing kit
containing a single blister: Battioni Pagani
gaskets and oil seals

11.3.4 BLADE SIZES

MODEL
BALLAST 3500
BALLAST 4500
BALLAST 6000
BALLAST 7500
BALLAST 9000
BALLAST 11000
BALLAST 13500
BALLAST 16000
Table 9
IMPORTANT: Ensure the blades received as replacements are of a length that is less than or equal to the nominal size
indicated by Table 9. Use only Battioni Pagani
p. 56
11.3.2 INSPECTION OF BLADES
To check the state of wear of the blades in the rotary blades vacuum pump
proceed as follows:
• Remove the threaded inspection plug (fig. 11);
• Rotate the rotor until a blades lines up with the inspection hole;
• Compare the height of the blade with the reference ring on the rotor;
• Replace the entire set of blades when the height is less than the
reference ring on the rotor.
original spare parts
®
BLADE NUMBER
original blades,
®
8
8
8
8
8
8
8
6
original spare parts.
®
BLADE MEASUREMENT
205x43x6,5
260x43x6,5
350x43x6,5
430x43x6,5
300x60x6,5
370x60x6,5
460x60x6,5
410x82,5x7,5
Tabla de contenido
loading

Tabla de contenido