Xylem Lowara e-LNEEE Manual De Instalación Y Funcionamiento página 18

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
en – Original instructions
Comm. Bus B2
18 RS485 port
A2
19 RS485 port
GND
20 Electronic
I/O terminals (versions 3~)
Item
Description
Fault signal C
25 COM - error
status relay
NO
24 NO Status relay
(error)
Motor
C
23 Common
running
contact
signal
NO
22 Normally open
contact
Auxiliary
15V 21 Auxiliary voltage
Voltage
supply +15 VDC
Supply
Analog input
S+
20 Actuator mode
0-10 V input
0-10V
S-
19 GND for 0-10 V
input
External
P1+ 18 Power supply
Pressure
external sensor
sensor [also
+15 VDC
Differential]
P1-
17 External sensor
4-20 mA input
External
P2+ 16 Power supply
pressure
external sensor
sensor
+15 VDC
P2-
15 Sensor 4-20 mA
input
External
Start 14 External
Start/Stop
ON/OFF input
Stop 13 External
ON/OFF input
reference
External
LoW+ 12 Lack water input Default short
Lack of
LoW- 11 Low water
18
RS 485 port2
2: RS485-2N
for external
B (-) active
comm.
only with
optional
module
2: RS485-2P
A (+) active
only with
optional
module
GND
Comments
In case of
power cables:
use the M20
cable gland
Closed: error
Open: no error
or unit off
In case of
power cables:
use the M20
cable gland
Open: motor in
operation
Closed: motor
not in
operation
15VDC, Ʃ
max. 100 mA
0÷10 VDC
GND,
electronic
ground (for
S+)
15VDC, Ʃ
max. 100 mA
4÷20 mA
15VDC, Ʃ
max. 100 mA
4÷20 mA
Default short
circuited Pump
enabled to
RUN
circuited Lack
Water
reference
Comm. Bus B2
10 RS485 port 2:
RS485-2N B (-)
active only with
optional module
A2
9 RS485 port 2:
RS485-2P A (+)
active only with
optional module
GND 8 Electronic GND
Comm. Bus B1
7 RS485 port 1:
RS485-1N B (-)
5
Operation
In case of co-existance of two or more of the following
conditions:
• high ambient temperature
• High liquid temperature
• duty points insisting on unit maximum power
• persisting undervoltage of mains, the lifespan of the
unit could be shortened and/or derating could occur.
Contact Xylem or the Authorised Distributor for
further information.
Also refer to the "Quick Startup Guide" and the
"Additional Installation, Operation and Maintenance
Instructions" of e-LNEE, e-LNES, e-LNTE and e-LNTS
pumps.
5.1
Wait times
WARNING: Electrical hazard
Contact with electric components may cause
death, even after the unit has been switched
off. Before any interventions on the unit, the
network voltage and any other input voltages
must be disconnected for the minimum time
indicated in the table.
Wait times
Mode (power supply)
Single-phase
Three-phase
WARNING: Electrical hazard
Frequency converters contain DC-link
capacitors that can remain charged even
when the frequency converter is not powered.
To avoid electrical hazards:
of water
detection:
enabled
RS 485 port2
for external
comm.
ACT, HCS
control mode:
RS 485 port1
for external
comm.
MSE, MSY
control mode:
RS 485 port 1
for multi-pump
systems
Minimum waiting
time [min]
4
5
Tabla de contenido
loading

Este manual también es adecuado para:

Lowara e-lneseLowara e-lnteeLowara e-lntse

Tabla de contenido