Unscrew the fuel inlet cover. Remove the inlet filter and rinse it in extraction naphtha removing any contamination. Replace the
filter.
Emptying the chamber of the pump (XVIII)
Unscrew the drain valve cover. Let the water flow out of the chamber of the pump. Incline the pump so as to empty the chamber
of the pump thoroughly. Rinse the chamber of the pump with clean water in order to remove any contamination. The chamber of
the pump must be emptied after each use of the pump. It is prohibited to store the pump with a full chamber.
Storage of the pump
Proper maintenance before storage permits a longer and more reliable operation of the pump. Empty the fuel tank, for example
using a plastic fuel pump, available in retail. Start the engine and leave it idling until it turns off. It will clean the carburettor from
fuel residues. Wait until the engine has cooled down. Empty the chamber of the pump of water. Rinse the chamber with clean
water, eliminating all contamination.
Remove the sparking plug. Pour a spoonful of oil through the socket to the two-stroke engine. Pull slightly the starting cable a few
times, which will permit to distribute the oil in the combustion chamber. Install the sparking plug. Clean the housing.
The pump must be stored in a cool, dry and well-ventilated place, far from sources of ignition.
Restarting the pump
Remove the sparking plug. Pull slightly the starting cable a few times, which will permit to clean the combustion chamber from oil
residues. Refill the fuel tank. Execute the engine start procedure.
Defect
The pump is not pumping water
The engine does not start
The engine starts, but the power is insufficient
Irregular operation of the engine
The exhaust system emits smoke instead of combus-
tion gas
O R I G I N A L
GB
Possible cause
The chamber of the pump has not been filled with
water
The water inlet pipe is leaking
The filter installed in the inlet pipe is clogged
Incorrectly realised starting procedure
The sparking plug is damp or rusted
Incorrect position of the choke lever
Dirty air filter
Incorrect distance between the electrodes of the
sparking plug
Incorrect adjustments of the carburettor
Incorrect proportions of the fuel mixture
Incorrect adjustments of the carburettor
I N S T R U C T I O N
Procedure
Fill the chamber of the pump with water.
Check the tightness of the water supply installation,
eliminate leakage.
Clean the filter and place it in another position in the
water tank
Observe the starting procedure
Clean or replace the sparking plug
Push the choke lever backwards
Clean the air filter
Clean or replace the sparking plug
Have the tool serviced in an authorised workshop
Observe the required proportions of the fuel mixture
Have the tool serviced in an authorised workshop
17