Technical Data
Description
Ports
Space requirement
Current measurement
Voltage measurement
Maximum length of supply cable to USB port
Energy manager input
External power supply (input)
External power supply (output)
Relay (voltage/load)
Temperature range Storage temperature
Temperature range Operating temperature
Type of article under test
Description of device function
Connection to the power supply
Installation/overvoltage category
Measurement category
Degree of contamination
Protection class
Protection class to IEC 60529
Type of protection
Operating conditions
Overall size of device (width x depth x height)
Weight
External current sensor (accessory and removable part)
Antenna (accessory and removable part)
Transmission frequency bands
Transmission power
Value
2 x USB, 1 x PLC, 1 x WiFi, 1 x Ethernet (ETH 0), 12 x CT input, 1 x RS485/CAN
Horizontal pitch 11.5 (1 HP is equivalent to 17.5 – 18 mm/0.7 inches)
0.5 A to 600 A (depending on current sensor), maximum cable length 3.0 m
100 V to 240 V (AC)
3.0 m
24 V (DC)/0.75 A
100 V to 240 V (AC)
24 V (DC)/18 W
Maximum 250 V (AC), maximum 3 A resistive load
–40 °C to 70°C
–20 °C to 45 °C (at 10 % to 90 % air humidity)
Control unit
Charge management for households
External power supply unit
III
III
2
IP20
DIN rail-mounted device
2
Continuous operation
159.4 mm x 90.2 mm x 73.2 mm
0.3 kg
ECS1050-L40P (EChun; 50 A input; 33.3 mA output)
ECS16100-L40M (EChun; 100A input; 33.3 mA output)
TT 100-SD (LEM, 100 A input; 33.33 mA output)
ECS24200-L40G (EChun; 200A input; 33.3 mA output)
ECS36400-L40R (EChun; 400A input; 33.3 mA output)
ECS36600-L40N (EChun; 600A input; 33.3 mA output)
HIRO H50284
2.4 GHz
58.88 mW
Technical Data
DE
EN
FR
IT
ES
PT
NL
SV
FI
DA
NO
EL
CZ
HU
PL
HR
SR
SK
SL
ET
LT
LV
RO
BG
MK
29