Technical data
Electrical data
Power
Rated current
Mains voltage
Mains connection
Mains frequency
Overvoltage category (IEC 60664)
Integrated residual current device
Protection class
Protection rating
Vehicle plug
Mechanical data
Weight of control unit with cable
Length of vehicle cable
1. The x stands for future design changes and is replaced by the letters A to W.
80
PMCP72x
1
7.2 kW
32 A, 1-phase
100 – 240 V
L, N, PE
50 Hz/60 Hz
II
Type A (AC: 30 mA) + DC: 6 mA)
I
IP55
Type 1
PMCP72x
1
3.4 kg
4.5 m
PMCP11x
1
11 kW/7.2 kW
16 A, 3-phase
32 A, 1-phase
100 – 240/400 V
L1, L2, L3, N, PE
50 Hz/60 Hz
II
Type A (AC: 30 mA) + DC: 6 mA)
I
IP55
Type 2
PMCP11x
1
4.0 kg