can occur if there is a leakage. This is why safety notices with information for a doctor should be kept
in a appropriate place. The operators are to be informed of the particular dangers of the gas and of
personal and other protection measures.
2.11 information on special types of gas
All parts which come into contact with oxygen must be completely free of oil and grease, to avoid
danger of ignition and explosion! Only use greases with oxygen approval. With acetylene do not use any
tubing or other equipment parts made of copper! Pay attention to the particular dangers of acetylene.
2.12 leakage of harmful gases and vapors
With open pressure relief valves and check valves e.t.a. or malfunctions, harmful gases and vapors
can escape. Ensure sufficient ventilation or evacuation. For hazardous media take particular safety
precautions. In particular the exit of the pressure relief and purge valves are to be released through
secure tubing and the materials are to be disposed safely and in an environmentally friendly manner.
2.13 Design changes on the pressure control device
Without written permission from the manufacturer, no changes, extensions or redesign on the pressure
control device or the equipment are to be carried out.
2.14 cleaning the gas device and disposal of the residue
Do not contaminate the equipment with oily rags or grease. Do not clean with solvents.

3. storage, transport

All parts must be packaged cleanly and be stored dust free, dry and well sealed. Correct packaging must
be used. Do not use any cleaning agents containing solvents! Before returning to the manufacturer it is
absolutely necessary that all components must be purged with inert gas, if they have been in contact with
corrosive or toxic gases.
4. Marking
On the nameplate (refer figure 1) there are: the type description (type), the materials of the regulator
body/seat material / diaphragm seal (mat.), the permissible nominal inlet pressure (p
specific outlet pressure area (p
the type of gas. The serial number of the device
is given as device specific identification on a
separate label in bar-code 128 and in plain text.
Caution! Only use equipment with an
application purpose which corresponds with
the type of gas and operating pressures marked
on the nameplate. Otherwise there is danger of
injury or danger to life and/or the danger of the
fittings being damaged.
5. gas panels
5.1 semi-automatic gas panels a 208/a 209
Description
The semi-automatic gas panel A 208/A 209 is essentially made up of two single stage regulators. The
automatic changeover from the empty cylinder to the full one takes place on the outlet pressure side
without external power. The cylinder feeding gas at the moment is shown by the changeover lever. If
used properly, this setup allows a continuous supply of gas. As a safety element against too high pressure
in the outlet pressure area, a pressure relief valve has been installed.
pressure ranges
Pressure relief valve: Opening pressure = P
front of the valves 50 µm wire mesh. The value given on the nameplate for the medium closing pressure
is an average. The changeover points of the regulator lie within the necessary pressure difference
which enables an automatic changeover without additional power. With higher outlet pressures, a
correspondingly higher pressure difference is required for reliable functioning. All values given are
), the manufacturer and the month of manufacture, a safety notice and
out
x 1.3 ... 1.5. Filters used: in the seat 10 µm wire mesh, in
4
Type: RB 200/1 14
Mat:
Brass/PVDF/PCTFE
p
: 40 bar
in
p
: 0,2 - 14 bar
out
1
English
), the instrument
in
Caution!
No user serviceable parts
inside. Refer all servicing to
authorized personnal only.