IMPORTANT REMARKS

TO REDUCE THE RISK OF SEVERE INJURY OR DEATH READ THE FOLLOWING REMARKS
CAREFULLY BEFORE PROCEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION TO
ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
INSTRUCTIONS COULD COMPROMISE THE CORRECT WORKING ORDER OF THE SYSTEM.
• These instructions are aimed at professionally qualified "INSTALL-
ERS OF ELECTRICAL EQUIPMENT" and must respect the local
standards and regulations in force. All materials used must be
approved and must suit the environment in which the installation
is situated.
• All maintenance operations must be carried out by professionally
qualified technicians. Before carrying out any cleaning or mainte-
nance operations make sure the power is disconnected at the mains
and the battery is disconnected.
• Attention! before moving dip "10" from the "OFF" position read
the paragraph "manoeuvring without safety devices" on page
11 carefully.
• The manufacturer accepts no liability for situations arising from
an installation which does not conform to the local standards and
regulations in force.
• This appliance must be used exclusively for the purpose for which it
has been made. "i.e. for the automation of fold-up garage doors"
Any non authorised modifications are to be considered improper
and therefore dangerous.
Use
The automation unit GL124EBSS is suitable for moving fold up garage
doors with the following dimensions:
- maximum height 2,7 m with a 3,0 m long guide
- maximum height 3,2 m with a 3,5 m long guide
- maximum height 4,2 m with a 4,5 m long guide
- maximum height 5,7 m with a 6 m long guide
IMPORTANT SAFETY INSTRUCTIONS
It is the responsibility of the installer to make sure that the following
public safety conditions are satisfied:
1) Make sure that there are no dangerous sharp edges.
2) Make sure that the end-user is aware that children and/or pets must
not be allowed to play within the area of a garage door installation.
If possible include this in the warning signs.
3) A correct earth connection is fundamental in order to guarantee
the electrical safety of the machine
4) If you have any questions about the safety of the door operating
system, do not install the operator. Contact your dealer for assist-
ance.
TECHNICAL DESCRIPTION OF THE AUTOMATION
311/GL124EBSS Propulsion unit complete with a radio control
receiver, buffer batteries and encoder controlled travel limits.
• Motor power supply 24 Vdc.
• The reduction unit stator is made of die cast aluminium and con-
tains a never ending screw and a helicoidal crown wheel made of
thermoplastic, lubricated with permanently fluid grease.
• Electronic programmer with a battery charger and an incorporated
radio receiver.
• Buffer battery NiMH for emergency movement.
• Courtesy light.
• Carter in reinforced fibre ABS fitted with:
- safety closing system for the battery well;
- accessible programming zone;
- removable terminal board cover;
- rubber cable clamp;
- tool for programming and removing the fuses.
• Protective cover and transparent inspection panel in shockproof
polycarbonate.
IMPORTANT REMARKS
TECHNICAL DESCRIPTION OF THE CHAIN GUIDE
320/GL124S35 Chain guide 3,5 m.
320/GL124S45 Chain guide 4,5 m.
320/GL124S60 Chain guide 6 m.
• Chain guide in extruded aluminium.
• Chain drive head in nylon fibre.
• Drive pinion in stainless steel.
• Transmission with chain tightener.
• Drag carriage in nylon fibre with wheel translation.
• Adjustable ceiling fitting.
USER INSTRUCTIONS
During the opening/closing manoeuvre check for correct operation and
activate the emergency stop button in case of danger. The appliance
must not be activated in the dark therefore make sure that the night
lights function correctly. The appliance can be manually released in
case of emergency (see manual manoeuvre on page 16).
Periodically check the moving parts for wear and tear and grease if
required, using lubricants which maintain their friction levels unaltered
throughout time and are suitable for temperatures of -20° to +70°C.
In case of failure or operational anomalies switch off the power at
the mains and disconnect the battery do not attempt to repair the
appliance yourself.
Periodically check the correct operation of all safety devices (photo-
electric cells etc.).
Eventual repair work must be carried out by specialised personnel
using original spare parts. The appliance is not suitable for continu-
ous operation and must be contained within the value stipulated (see
technical data on page 60).
INSTALLATION INSTRUCTIONS
The minimum controls which may be installed are SEQUENTIAL-STOP,
these controls must be installed at a height between 1,5 and 1,8 m
an in a location not accessible to children. Warning sighs or adhesive
should be placed near the commands indicating the points where the
risk of crushing exists.
Important: Before starting with the installation of the system check
that the structure which is to be automated is in good working order
and respects the local standards and regulations in force.
To this end make sure that the garage door is sufficiently rigid (if
necessary reinforce the structure) and check that the door guide rails
slide freely (we advise you to lubricate all moving parts).
Check that the minimum distance between the open door and the
ceiling is not less than 60 mm (fig. 2).