IMPORTANT REMARkS

TO REDUCE THE RISk OF SEVERE INJURY OR DEATH READ THE FOLLOWING REMARkS CARE-
FULLY BEFORE PROCEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION TO
ALL THE PARAGRAPHS MARkED WITH THE SYMBOL
INSTRUCTIONS COULD COMPROMISE THE CORRECT WORkING ORDER OF THE SYSTEM.
• These instructions are aimed at professionally qualified "installers of
electrical equipment" and must respect the local standards and regu-
lations in force. All materials used must be approved and must suit the
environment in which the installation is situated.
• All maintenance operations must be carried out by professionally qualified
technicians. Before carrying out any cleaning or maintenance operations
make sure the power is disconnected at the mains.
• This appliance must be used exclusively for the purpose for which it has
been made. "i.e. for the automation of hinged gates" with one or two gate
leaves, max. length 2,5 m (3,5 m with an electric lock) max. weight 200 kg.
• The unit may be fitted both to the right and to the left of the passageway.
This product and all its relative components has been designed and
manufactured by Cardin Elettronica who have verified that the product
conforms in every aspect to the safety standards in force.
Any non authorised modifications are to be considered improper danger-
ous and the complete responsibility of the installer.
Caution! a mechanical stop buffer must be installed in the closing
position (pos. 1, fig. 5).

IMPORTANT SAFETY INSTRUCTIONS

It is the responsibility of the installer to make sure that the following public
safety conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from the
main road to eliminate possible traffic disruptions.
2) The motor must be installed on the inside of the property at a height
between ,5 and ,8 m and not on the public side of the gate. The gates
must not open onto a public area.
3) The gate operator is designed for use on gates through which vehicles
are passing. Pedestrians should use a separate entrance.
4) The gate must be in full view when it is operating therefore controls
must be situated in a position where the operator can see the gate at all
times.
5) At least two warning signs (similar to the example
on the right) should be placed, where they can be
easily seen by the public, in the area of the system
of automatic operation. One inside the property and
one on the public side of the installation.
These signs must be indelible and not hidden by any
objects (such as tree branches, decorative fencing
etc.).
6) Make sure that the end-user is aware that children
and/or pets must not be allowed to play within the area of a gate instal-
lation. If possible include this in the warning signs.
7) Whenever a fully open gate leaf comes within ≤ 500 mm of a fixed
structure the space must be protected by an anticrush buffer.
8) If you have any questions about the safety of the gate operating system,
do not install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
• 200/BL3924ESB self-locking reduction unit with incorporated encoder.
• 200/BL3924ERB reversable reduction unit with incorporated encoder.
- Direct current drive motor max. 24 Vdc.
- High performance, robust, permanently lubricated four-stage epicycloid
reduction unit. Internal manual release system (Cardin patent) managing
the release of the gears form the gate (emergency manoeuvre).
- A plastic framework is fixed to the reduction unit chassis and houses the
electronic programmer, the battery charger, the radio frequency module,
the toroidal transformer and the special Cardin emergency batteries.
- Motor support base in zinc-plated steel
- Articulated operator arm in spray-painted cast aluminium
ACCESSORIES
980/xLSEC - Electric locking device 2 Vac/dc
IMPORTANT REMARkS
USER INSTRUCTIONS
During the opening/closing manoeuvre check for correct operation and
activate the emergency stop button in case of danger.
During blackouts the gate can be released and manually manoeuvred using
the supplied release key (see manual release pag. 6).
Periodically check the moving parts for wear and tear and grease if required
using lubricants which maintain their friction levels unaltered throughout
time and are suitable for temperatures of -20 to +70°C. In case of failure
or operational anomalies switch off the power at the mains do not attempt
to repair the appliance yourself.
Periodically check the correct operation of all safety devices (photoelectric
cells etc.). Eventual repair work must be carried out by specialised person-
nel using original spare parts. The appliance is not suitable for continuous
operation and must be adjusted according to the model (see technical
data on page 52).

INSTALLATION INSTRUCTIONS

The minimum controls which may be installed are OPEN-STOP-CLOSE,
these controls must be installed in a location not accessible to children and
outside the opening range of the gate.
Before starting the installation of the system check that the structure which
is to be automated is in good working order and respects the local standards
and regulations in force.
To this end make sure that the gate is sufficiently rigid (if necessary reinforce
the structure) and that it pivots easily.
You are advised to grease all the moving parts using lubricants which maintain
unaltered friction characteristics over a period of time and are suitable for
temperatures of -20 to +70°C.
• Check the safety measures between the fixed and moving parts:
- a minimum space of 30 mm must always be left along the entire dis-
tance between the gate and the support column measured throughout
the entire opening angle of the gate.
- make sure that the space between the bottom of the gate and the
pavement never exceeds 30 mm throughout the entire opening angle
WARNING
of the gate.
AUTOMATIC OPENING
• The surface of the gate must not feature openings which allow a person's
kEEP CLEAR
hand or foot to pass through.
• Check the exact positioning of the pivots, and their good working order
(the upper and lower hinges/pivots must be aligned on the same axis).
• Work out the run of the cables according to the command and control
CHILDREN OR PETS MUST NOT
devices fitted and make sure the system conforms to the local standard
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
and regulations in force (see installation example fig.1 pag. 2).
• Check that the appliance is suitable for the size, weight and duty cycle
of the gate to which it is to be applied (see duty cycle on page 52)
ASSEMBLY PROCEDURE
The unit may be positioned either to the right or to the left of the pas-
sageway:
• Move the gate/s to the closed position.
• Choose the value "A" (fig. 4) according to the required opening angle
and work out (depending on the structural characteristics of the gate) at
what height the front bracket will be fitted to the gate.
Once the position has been established pass the connecting, power and
safety device cables through the opening "C" (fig. 6) in the column and
fasten down the motor support plate using four M8 screws and steel Ø14
rawlplugs. Make sure that the support bracket "D" (fig. 6) is in square.
• Pass the cables "F" (fig. 7) through the upper cable guide "E" and fasten
them inside the base using the cable clamps "G" and the screws "H".
Insert the lower cable guide "E".
• Fasten the geared motor (fig. 8) to the base plate using the screws "G"
and self-locking nuts.
• Connect the power, safety device and the second motor/encoder "k" to
the electronics card (fig. 9)
7
IMPORTANT REMARkS
. NOT READING THESE IMPORTANT
Tabla de contenido
loading

Este manual también es adecuado para:

200/bl3924esb200/bl3924erb

Tabla de contenido