7.7
Program description
7.7.1
Key to symbols
Icon
Description
"Options" button
Provides different options depending on the current
screen.
"Passed" icon
Indicates a positive test result.
Pass on Limits" icon
Indicates a positive test result just within the limits.
"Not passed" icon
Indicates a negative test result, e. g. because of ex-
cessive leakage in the return from the injector.
"Error" icon
Compressed air supply inadequate (for remedy, see
section 7.9).
"Test steps" icon
Hides and displays the test steps.
"Back" button
Navigate to the previous screen.
"Quieter" button
Decreases the volume.
"Louder" button
Increases the volume.
"Open applications" button
Displays all open applications.
"Home" button
The home screen is displayed.
7.7.2
Home Screen (fig. 32)
The start screen appears after logging in. The following
functions can be executed:
$
Touch the Bosch logo to open the injector selec-
tion screen (see sec. 7.9.3).
$
"Log" button; select to view previously generated
logs.
$
'Options" button; select to access different op-
tions like the settings.
Fig. 32:
Home Screen
Robert Bosch GmbH
Operation | EPS 118 | 73
7.7.3
Select CRI/CRIN or piezo CRI (fig. 33)
i
All of the tests sequences that are in the database
are displayed in the left column. Move the list up or
down to go to the desired CRI/CRIN or piezo
CRI Piezo. Enter search criteria such as the brand
name and/or type part number into the white input
box to filter the list, and only those CRI/CRINs or
piezo CRIs are displayed that meet the search crite-
ria.
1. Search and select the CRI/CRIN or piezo CRI in the
list.
The information for testing and clamping CRI/CRINs
or piezo CRIs is displayed in the right window.
Select <Start>.
Fig. 33:
Select Injector Screen
en
|
1 689 989 220
2016-02-05