Installation
Chemical Injection Supply
System
WARNING
Wear eye and hand protection when
handling chemicals; always avoid direct
contact with raw chemicals. Read the
manufacturer's directions for accidental
contact before handling chemicals. Ensure
an eye-rinse facility and an emergency
shower are within easy reach. Check at
regular intervals for chemical leaks.
Injection Point
PVC Pipe
30
Undiluted chemical dripping can damage the
machine. Therefore, all chemical supply
dispenser pumps should be mounted below the
washer's injection point. All dispenser tubing
should also run below the injection point.
Loops do not prevent drips if these instructions
are not followed. Failure to follow these
instructions could damage the machine and
void the warranty. See Figure 15 for a typical
chemical supply injection system.
SW016
Chemical Dispenser
Pump Outlet
Figure 15
F232058