Installation
Supply Dispensing
(OPL Machines Only)
WARNING
Dangerous Chemicals. May damage eyes
and skin. Wear eye and hand protection
when handling chemicals; always avoid
direct contact with raw chemicals. Read
the manufacturer's directions for
accidental contact before handling
chemicals. Ensure an eye-rinse facility
and an emergency shower are within easy
reach. Check at regular intervals for
chemical leaks.
Supply Dispensing
Number of dry supply
compartments
Number of liquid supply
connections (OPL only)
Liquid supply connection size
IMPORTANT: Undiluted chemical dripping can
damage the machine. All chemical injection supply
dispenser pumps and dispenser tubing should be
mounted below the washer's injection point. Loops
do not prevent drips if these instructions are not
followed.
IMPORTANT: Failure to follow these instructions
could damage the machine and void the warranty.
Connection of External Liquid Supplies
18 – 80 Pound OPL Models
1. Facing the rear of the machine, locate the
1-1/2 inch opening found at the upper right-hand
side of the valve panel. Refer to Figure 21.
38
W363
18 – 80
125
3
0 or 5
(optional)
4
5
5/16 in.
5/8 in.
(8 mm)
(15.9 mm)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
C VALVE PANEL – REAR VIEW
1
External Supply Hose Opening
Figure 21
2. Gather external supply hoses and pull through
opening.
3. Locate the 4 capped nozzles on the rear of the
liquid supply dispenser and remove caps. Refer
to Figure 22.
3 AND 4
2
Nozzles:
1
Detergent
2
Bleach
3
Sour
4
Soft
5
Speciality
Figure 22
1
B006I
B006I
1
5
U149M
U149M
F232135