Installation
Electrical Installation (
Voltage Designation
M
550-575
M*
550-575
N
440-480
N*
440-480
P
380-415
35
P*
380-415
Q
200-240
Q*
200-240
T
200-240
T*
200-240
M
550-575
M*
550-575
N
440-480
N*
440-480
P
380-415
50
P*
380-415
Q
200-240
Q*
200-240
T
200-240
T**
200-240
M**
550-575
N**
440-480
85
P**
380-415
Q**
200-240
Note: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.
*Models with 1305-series drive.
**Models with 1336-series drive.
28
Continued)
Electrical Specifications
50-60
3
3
4
50-60
3
3
6
50-60
3
3
4
50-60
3
3
6
50-60
3
3
4
50-60
3
3
6
50-60
3
3
10
50-60
3
3
10
50-60
1
2
13
50-60
1
2
19
50-60
3
3
6
50-60
3
3
10
50-60
3
3
4
50-60
3
3
11
50-60
3
3
4
50-60
3
3
11
50-60
3
3
10
50-60
3
3
19
50-60
1
2
18
50-60
1
2
26
60
3
3
13
50-60
3
3
13
50-60
3
3
13
50-60
3
3
24
Standard
15
14
3x2.5
10
14
3x2.5
15
14
3x2.5
15
12
3x4
15
14
3x2.5
15
12
3x4
15
14
3x2.5
20
12
3x4
15
14
2x2.5
30
10
3x6
15
14
3x2.5
15
14
3x2.5
15
14
3x2.5
20
12
3x4
15
14
3x2.5
20
12
3x4
15
14
3x2.5
30
10
3x6
25
10
2x6
50
6
2x16
25
10
3x4
25
10
3x4
25
10
3x4
40
8
3x6
Electric Heat
Not available in this voltage.
Not available in this voltage.
32
35
8
25
30
10
32
35
8
22
30
10
50
50
8
38
50
6
Not available in this voltage.
Not available in this voltage.
Not available in this voltage.
Not available in this voltage.
43
50
8
38
50
6
43
50
8
33
40
8
76
80
4
56
70
4
Not available in this voltage.
Not available in this voltage.
Not available in this voltage.
55
60
6
55
60
6
105
110
2
3x10
3x6
3x10
3x6
3x10
3x16
3x10
3x16
3x10
3x10
3x25
3x25
3x16
3x16
3x35
F232058