1
120 ± 12
V.A.C.
5
STANDARD 120 VOLT, 60 HERTZ, 3-WIRE
EFFECTIVELY GROUNDED CIRCUIT
1
L1
2
Ground
3
Neutral Side
4
Round Grounding Prong
5
Neutral
Figure 17
DO NOT OPERATE OTHER APPLIANCES ON
THE SAME CIRCUIT. DO NOT OVERLOAD
CIRCUITS!
Do not operate both a washer and gas dryer on the
same circuit. Use separately fused 15 Amp circuits.
WARNING
To reduce the risk of electric shock or fire,
DO NOT use an extension cord or an
adapter to connect the washer to the
electrical power source.
801561
2
3
0
V.A.C.
120 ± 12
V.A.C.
4
D799I
W031
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Water Supply Requirements
WARNING
Under certain conditions, hydrogen gas may
be produced in a hot water system that has
not been used for two weeks or more.
HYDROGEN GAS IS EXPLOSIVE. If the hot
water system has not been used for such a
period and before using the washer, turn on
all hot water faucets and let the water flow
from each for several minutes. This will
release any accumulated hydrogen gas. The
gas is flammable. Do not smoke or use an
open flame during this time.
NOTE: Water supply faucets must fit standard
19.1 mm (3/4 in.) female garden hose couplings.
DO NOT USE SLIP-ON OR CLAMP-ON
CONNECTIONS.
NOTE: Water supply faucets should be readily
accessible to permit turning them off when washer
is not being used.
Installation
W029
15