Installation
Control Function Test
The washer-extractor should be cleaned after
the installation is complete. A function test
should then be executed on the unloaded
machine:
1. Verify that power supply voltage and
phase are correct in accordance with the
washer-extractor's requirements. If the
Premium Wet Clean Module is installed,
3-phase power must be provided.
2. Open manual shut-off valves to
the washer-extractor.
3. Press the Emergency Stop button.
4. Apply power to the washer-extractor.
5. Release the Emergency Stop button.
6. Check the door interlock before
starting operation:
a. Attempt to start the washer with the
door open. The washer-extractor should
not start with the door open.
b. Close the door without locking it and
attempt to start the washer. The washer
should not start with the door unlocked.
c. Close and lock the door and start a
cycle. Attempt to open the door while
the cycle is in progress. The door
should not open.
If the door lock and interlock are not
functioning properly, call a service technician.
7. For standard processing, select Cycle 01
by pressing key 0 and key 1 on the keypad.
Then press the Start key.
Run a complete cycle, checking operation of
water inlet valves, drain, and extract functions.
42
F232058