Electrical Power Supply Connection; Electronic Control Terminal Boards - myone ARIA Manual De Instalación Y Mantenimiento

Ocultar thumbs Ver también para ARIA:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

6.2 ELECTRICAL POWER SUPPLY CONNECTION

L
H
+24V
+24V
- 24V
TS
OS
+24V
- 24V
TS
CS
+24V
-24V
OP-E
+24V
-24V
OP-I
+24V
-24V
Use a power cable for connection to the power supply mains.
The power supply cable can be connected to an electrical socket (not supplied by us), prepared near the automation head.
If an electrical socket is not present near the automation, connect to the electrical mains as follows: perforate the aluminium box at the top, protect passage of
the power supply cable using cable glands (not supplied by us) to eliminate sharp edges which could damage the power cable, and connect the cable to the
electricity supply.
Connection to the electrical power supply, in the section outside automation, must takes place via an independent duct and separate from the connections to
the command and safety devices.

6.3 ELECTRONIC CONTROL TERMINAL BOARDS

When you connect the safety devices, remove the jumpers of the corresponding terminals.
Terminals J20 (grey)
Description
L / H /+24V / -24 V
BUS connection (not used)
Terminal J3 (green)
Description
TS
Test output (+24V). Connect the safety devices with testing (compliance with standard EN 16005), as indicated in the following
chapters.
N.B. For devices without testing, connect the N.C. contact to the TS/OS terminals.
TS /OS
N.C. safety contact in opening side B (right hand side of automation view). When the door is opening, opening the contact cau-
ses slowing of the door in the last 500 mm (the safety function of the OS terminal can be modified using the advanced parame-
ters menu).
N.B. Connect the safety devices with testing (see TS terminal) and remove the TS/OS jumper.
+24V / - 24V
24 Vdc output for external accessories supply. Maximum absorption of 1 A corresponding to the sum of all the terminals (+/- 24V).
Terminals J10 (black)
Description
TS
Test output (+24V). Connect the safety devices with testing (compliance with standard EN 16005), as indicated in the following
chapters.
N.B. For devices without testing, connect the N.C. contact to the TS/CS terminals.
TS /CS
N.C. safety contact in opening side A (left hand side of automation view). When the door is opening, opening the contact causes
slowing of the door in the last 500 mm (the safety function of the CS terminal can be modified using the advanced parameters
menu).
N.B. Connect the safety devices with testing (see TS terminal) and remove the TS/CS jumper.
+24V / -24V
24 Vdc output for external accessories supply. Maximum absorption of 1 A corresponding to the sum of all the terminals (+/- 24V).
Terminal J5 (green)
Description
OP-E
N.O. opening contact side B (external side of automation view).
+24V / -24V
24 Vdc output for external accessories supply. Maximum absorption of 1 A corresponding to the sum of all the terminals (+/- 24V).
Terminals J9 (black)
Description
OP-I
N.O. opening contact side A (internal side of automation view).
+24V / -24V
24 Vdc output for external accessories supply. Maximum absorption of 1 A corresponding to the sum of all the terminals (+/- 24V).
12
USB
PP
S
+24V
-24V
I3
IO2
IO1
+24V
-24V
+LK
-LK
J1
- MOT +
ENC
ENTER
ESC