Low Energy Adjustment - myone ARIA Manual De Instalación Y Mantenimiento

Ocultar thumbs Ver también para ARIA:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

7

Low Energy Adjustment

For Low Energy settings, execute the following operations:
- adjust PUSH force ≤ 5;
- Adjust the VOP opening speed to open the door (from 0° TO 80°) In the times indicated in the table;
- Adjust the VCL closure speed to close the door (from 90° TO 10°) In the times indicated in the table;
APERTURA / OPENING
Speed settings for automated leaf doors with low voltage
The table displays the minimum opening time (in seconds)
Length of door
50 kg
0,75 m
3,0 s
0,85 m
3,0 s
1,00 m
3,5 s
1,20 m
4,0 s
16
CHIUSURA / CLOSING
da 0° a 80° ≥ 3 s
(vedi tabella / see table)
Weight of door
60 kg
70 kg
3,0 s
3,0 s
3,0 s
3,5 s
3,5 s
4,0 s
4,5 s
4,5 s
da 90° a 10° ≥ 3 s
(vedi tabella / see table)
80 kg
90 kg
3,0 s
3,5 s
3,5 s
4,0 s
4,0 s
4,5 s
5,0 s
5,5 s