Start-up procedure for automatic lead door
11.1 Preliminary checks
At the end of the installation activities, manually move the doors and check movement is regular and friction free.
Check the structure is solid and correctly fasten all the screws.
Check the electrical connections are all correct.
11.2 Before connecting possible safety devices, leave the jumpers on the safety terminals of the electronic control (TS-CS, TS-OS).
N.B. The first opening and closure manoeuvre is carried out with low speed to enable automatic detection of the stop measurements.
11.3 To ensure the electronic control has the factory settings, restore the values using the menu:
MEM > FSET > YES (confirm by pressing ENTER for 1 second).
11.4 Execute menu adjustments as indicated in chapter 9. Use the OPEN key to give the opening commands and check the door is working properly.
N.B. The automation automatically recognises possible obstacles during the closure (movement inversion) and opening manoeuvre (movement stoppage).
11.5 Connect the command and safety devices one at a time to protect the door closure manoeuvre, as indicated in chapter 8.5 and checking its correct
operation.
N.B. Check the passage compartment is correctly protected from safety sensors, in compliance with the provisions of the European standard EN16005
(Annex C).
11.6 Connect the safety devices one at a time to protect the door opening manoeuvre, as indicated in chapter 8.6 and checking its correct operation.
N.B. In the event of distances between the door and the fixed parts, comply with the European standard EN16005 (chapter 4.6.2.1.a), the safety sensors in
opening are not necessary (X ≤ 100 and Y ≥ 200).
11.7 Connect the functions selector as indicated in chapter 9.4.
11.8 When start-up is complete, deliver the use instructions to the manager of the automatic door, including the warnings and information necessary to
maintain safety and functionality of the automatic door.
N.B. The manufacturer of the automatic leaf door must add its identification label of the system.