8 . OPERATING PROBLEMS

Before carrying out any repair or maintenance
CAUTION !
work, DISCONNECT THE PUMP FROM THE
ELECTRICITY SUPPLY.
To prevent an operating incident with respect to the parts under-
pressure, these should be decompressed in advance (ventiation of
anti-reflux device and draining of reservoir, if necessary with the
hand pump).
OPERATING
TROUBLE
8.1. THE PUMP FAILS TO START
8.2. THE PUMP DOES NOT
DELIVER OR THERE IS
INSUFFICIENT FLOW
8.3. CURRENT INPUT TOO
HIGH
8.4. DISCHARGE HEIGHT TOO
SMALL
8.5. INPUT POWER TOO HIGH
8.6. THE PUMP OPERATES IN
AN IRREGULAR MANNER
AND MAKES A LOT OF
NOISE
CAUSE
a) Lack of current :
b) Pump inlet obstructed :
c) Motor winding or conducting
wire in bad condition :
d) Non-return valve obstructed :
e) Winding temperature too high,
winding temperature probe
cut :
f) The degassing pipe of the pump
is obstructed :
a) Pump
inlet
or
impeller
obstructed :
b) Incorrect rotation direction :
c) Internal components worn
(wheel, bearing) :
d) Non-return valve obstructed :
e) Excessive drop in water level in
reservoir :
f) The discharge valve is not open
completely :
g) Unacceptable air or gas
content in the pumped liquid :
a) Incorrect rotation direction :
b) Operating voltage too low :
c) Operates on 2 phases :
d) Motor winding or electric cable in
bad condition :
e) Faulty motor bearing :
a) See 8.2-a :
b) Incorrect rotation direction :
c) See 8.2-c :
d) Operates on 2 phases :
e) Non-return valve obstructedé :
f) See 8.2-g :
g) See 8.2-h :
a) Incorrect rotation direction :
b) See 8.2-c :
c) Faulty motor bearing :
a) See 8.2-a :
b) See 8.2-c :
c) See 8.2-e :
d) See 8.2-h :
e) Faulty motor bearing :
f) Vibrations due to installation :
a) Check the electrical unit.
b) Clean the pump inlet in the tank.
c) Contact the Salmson after-sales service.
d) Clean the non-return valve.
e) After cooling, the motor restarts automatically.
f) Clean the degassing pipe.
a) Remove the deposits in the pump and/or in the reservoir.
b) Switch two phase wires to supply (three-phase only).
c) Replace worn parts.
d) Clean the non-return valve.
e) Check the level controller.
f) Open the valve completely.
g) Contact the Salmson after-sales service.
a) Switch two phase wires to supply (three phase only).
b) Contact the electricity company responsible for the network.
c) Blown fuse - Check the electrical connections.
d) Contact the Salmson after-sales service.
e) Contact the Salmson after-sales service.
a) Remove the deposits in the pump and/or in the reservoir.
b) Switch two phase wires to supply (three phase only).
c) Replace worn parts.
d) Blown fuse - Check the electrical connections.
e) Clean the non-return valve.
f) Open the valve completely.
g) Contact the Salmson after-sales service.
a) Switch two phase wires to supply (three-phase only).
b) Replace worn parts.
c) Contact the Salmson after-sales service.
a) Remove the deposits in the pump and/or in the reservoir.
b) Replace worn parts.
c) Check the level controller.
d) Contact the Salmson after-sales service.
e) Contact the Salmson after-sales service.
f) Check the pipes and the anti-vibration collars.
10