WARNING
Head and foot injuries due to lack of protect-
ive equipment!
Danger of (serious) injuries during work. Wear the
following protective equipment:
• Safety shoes
• Safety helmet must be used if lifting equipment
are used!
NOTICE
Only use lifting equipment in a technically
sound condition!
Only use lifting equipment in a technically sound
condition for lifting, lowering and transporting the
pump. Ensure that the pump does not become
jammed during lifting and lowering. Do not exceed
the max. permissible bearing capacity of the lifting
equipment!
CAUTION
Soaked packaging may tear!
As a result, the device may fall on the ground unpro-
tected and may be damaged. Soaked packaging
must be lifted carefully and replaced immediately!
Only remove the outer packaging at the place of util-
isation to ensure that the pump is not damaged during
transport. Use tear-proof plastic sacks of sufficient size
to package used pumps for transport in a leak-proof
manner.
The following points must also be observed:
Fig. 2: Attachment point
▪ Adhere to the applicable national safety regulations.
▪ Use legally specified and approved lifting gear.
▪ Select the lifting gear based on the existing conditions
(weather, attachment point, load, etc.).
▪ Only attach the lifting gear to the attachment point. Fix
with a shackle.
Installation and operating instructions Rocsan neo
Transportation and storage
▪ Use lifting equipment with sufficient bearing capacity.
▪ The stability of the lifting equipment must be ensured
during operation.
▪ When using lifting equipment, a second person must be
present to coordinate the procedure if required (e.g. if
the operator's field of vision is blocked).
5.3
Storage
DANGER
Danger due to fluids hazardous to health!
If the pump is used in fluids hazardous to health, de-
contaminate the pump after dismantling and before
carrying out any other work! There is danger to life!
Observe the specifications in the work regulations!
The operator must make sure that the personnel has
received and read the work regulations!
WARNING
Sharp edges on the impeller and suction port
Sharp edges can form on the impeller and suction
port. There is danger of limbs being cut-off! Pro-
tective gloves must be worn to protect from cuts.
CAUTION
Total damage due to moisture ingress
Moisture ingress in the power supply cable damages
the power supply cable and the pump! Never im-
merse the end of the power supply cable in a fluid
and firmly seal it during storage.
Newly supplied pumps can be stored for one year. Con-
tact customer service to store the pump for more than
one year.
The following must be observed for storage:
▪ Securely position the pump on a firm bearing surface.
Store pumps with pump support foot in an upright pos-
ition, store pumps without pump support foot in a hori-
zontal position. Secure the pump against falling over
and slipping!
▪ The max. storage temperature is -15 °C to +60 °C at a
max. relative humidity of 90 %, non-condensing.
Frost-proof storage at a temperature of 5 °C to 25 °C
with relative humidity of 40 % to 50 % is recommen-
ded.
▪ Do not store the pump in rooms in which welding work
is carried out. The resulting gases or radiation can cor-
rode the elastomer parts and coatings.
▪ Seal the suction and pressure connection tightly.
▪ Protect power supply cables against kinking and dam-
age.
en
39