Figure 30 – Circuit Breakers – 8KPRO
1 - 120V Circuit
Breaker
3. Move the fuel shutoff valve to the ON position (see
Figure 31).
Figure 31 – Fuel Shutoff Valve in the ON Position
NOTICE
This generator is equipped with an automatic
choke for starting. This system is always on and
cannot be turned off. Do not attempt to make
adjustments to the automatic choke or any other
carburetor adjustments. Tampering with the
automatic choke system may void your warranty.
See an authorized Westinghouse service center for
more information.
2
2 - Main Breaker
OPERATION
4. Press the start button on the remote start key fob.
5. The generator will turn over for 3 to 5 seconds and
start.
6. An engine warmup delay is programmed into the
remote start cycle. After the generator is running,
there will be a delay of electrical output for 15
seconds.
7. If the engine fails to start within 3 to 5 seconds, the
engine will attempt to start five additional times.
If the generator failed to start, the remote start
indicator light will flash.
8. If the generator fails to start after a total of six
attempts, the start button on the key fob must be
pushed again to begin another cycle of six start
attempts.
STOPPING THE GENERATOR
USING REMOTE START
1. Make sure there is no load to any of the generator
outlets.
2. Press the stop button on the remote start key fob.
3. The generator will run for an additional 15 seconds
as it goes through a cooldown cycle before shutting
off.