QUICK GUIDE:

Install the gearmotor , the control devices ( key switch or push button) and safety devices (emergency stop, photocells, sensitive
edges and flashing light) and then connect the unit as follows:
Turn the unit on and check that the input voltage on terminals 1and 2 is 230Vac, and the output voltage on terminals 5 and 6 is
24Vdc; the LEDs on 'active' inputs should be on and the OK LED should blink at 1 second intervals. The OK ENCODER LEDs
signal each movement of the gate/door.
Check movement direction by pressing the CLOSE key twice: if the gate/door opens turn the unit off, turn the MOTOR connector
180° and turn the jumper J8 in the opposite position.
To set up a new installation, or if the control card memory has been cancelled carry out procedures 1 and 2 below:
1) Press the CLOSE key on the card for a moment.
2) Set the FUNCTIONS and PROGRAMMING dip-switches as indicated and then press the CLOSE key on the card.
If dip switch 10 is OFF, point "C" is positioned 5 cm from point "0"; if it is ON, point "C" corresponds to "0".
1 2 3 4 5 6 7 8 9 10
Wait for the search procedure to finish (slow closing, slow opening ending with quick reclosing)
Set the FUNCTION dip-switches as required with the PROGRAMMING switches both "OFF".
Switches 1-2: Off Off
On Off
Off On
On On
Switch 3
On
Switch 4
On
Switch 5
On
Switch 6
On
Switch 7
On
Switch 8
On
Switch 9
On
Switch 10
On
If the automatic mode is selected (Switch 2 "On") Pause Time is preset at 30 seconds. To alter it see Chapter 4.4.
Adjust the CLUTCH trimmer until the required triggering threshold is reached (thrust is increased by turning it clockwise).
18
Do not install the motor without the "Mechanical travel stop devices"!
PROGRAMMING
FUNCTIONS
CLOSE KEY
1 2
3
"OK" LED
MOTOR
315mAT
FUSE
8 A
Switch 10 "OFF"
1 2
recommended for sliding
gates "RO1024"
= " Hold to run control " functioning mode
= "Semiautomatic" functioning mode
= "Automatic" functioning mode (Automatic Closing)
= "Automatic + Close Always" functioning mode
= Condominium functioning mode
= Cancel STOP in the step-by-step cycle
= Preflashing
= Flashing also in Pause
= Recloses immediately after Photocell (only if in the Automatic functioning mode)
= Safety device (Photocell) also in opening
= Safety devices (Photocell and Photocell 2) also at the beginning of each movement
= Automatic realignment, if required, when power returns
OK ENCODER
J8
CLUTCH
44
43
42
41
14
PARTIAL OPENING
13
TIMER OPENING
12
SbS
11
PHOTOCELL 2
PHOTOCELL
10
STOP
9
8
7
6
+ (24v)
5
- (0 v)
FUSE
4
+
-
3
FUSE
2
3,15 A
1
1 2 3 4 5 6 7 8 9 10
AERIAL
2ND CH.
RADIO
PARTIAL OPENING
TIMER OPENING
SbS
PHOTOCELL 2
PHOTOCELL
STOP
GATE OPEN INDICATOR
COMMON
+(24v)
24 Vdc
MAX 200 mA
LUCY 24 Vdc
MAX 25 W
230 Vac
50-60 Hz
Switch 10 "ON"
1 2
recommended for
sectional or sliding doors
"CR2040"

Hide quick links:

Tabla de contenido
loading

Este manual también es adecuado para:

Robo ro 1000Robo ro 1010Robo ro 1040Robo ro 1124

Tabla de contenido