Menu
Default setting
Normal operation
Energized
A1 relay
Normal operation
A2 relay
Calibration pass-
_ _ _ 1
word
Settings password _ _ _ 2
LCD setting
On
SIL status
Off
Language
EN
Auto-calibration
Off
Function key
Faults
Interface
Default setting
Fault current
1.2 mA
Warning
Off
Warning current
3.0 mA
Warning cycle
10 sec
interval T1
Warning cycle
1 sec
interval T2 (warn-
ing current)
Maintenance sig-
static
nal
Maintenance cur-
3.4 mA
rent
Analog offset
0 mA
Analog span
0 mA
0
®
HART
address
126
1)
Modbus address
even (default)
1)
Modbus parity
Modbus bau-
9600 bps
1)
drate
126
®
PROFIBUS
1)
address
1) Fieldbus interfaces are not in accordance with the BVS 13 ATEX
G001 X. Using the fieldbus interface no relays are available.

15.3 Sensor-specific values

See sensor data sheet for further specifications.
Dräger Polytron
Range
Energized / Not
energized
On / Off
On / Off
DE / EN / FR / ES /
RU / ZH
On / Off
Graph, fault, warn-
ing, vitality, bump
test
Range
0 to 3.5 mA
On / Off
0 to 3.5 mA
5 to 60 sec
1 to (T1-1) sec
static / dynamic
0 to 3.5 mA
-0.5 to 0.5 mA
-0.5 to 0.5 mA
0 to 15
2-126
even, odd parity,
no parity
9600 or 19200 bps
2-126
®
8000 Series
®
15.3.1 Polytron
8100 EC
Menu
Default setting
A1 Alarm
Depending on the
sensor
A2 Alarm
Depending on the
sensor
Hysteresis for A1
0
alarm at direction
rising
Hysteresis for A2
0
alarm at direction
rising
Calibration inter-
Depending on the
val [days]
sensor
Display capture
20.9 Vol% (O
offset
Display capture
-0.25 Vol% (O
low
Display capture
0.25 Vol% (O
high
Full scale deflec-
25 Vol% (O
tion
O
LS)
2
®
15.3.2 Polytron
8200 CAT DrägerSensor
Menu
Default setting
A1 Alarm
20 % LEL
A2 Alarm
40 % LEL
Hysteresis for A1
1 % LEL
alarm at direction
rising
Hysteresis for A2
1 % LEL
alarm at direction
rising
Calibration inter-
180
val [days]
Display capture
0 % LEL
offset
Display capture
-5 % LEL
low
Display capture
2 %LEL
high
Full scale deflec-
100 %LEL
tion
®
15.3.3 Polytron
8200 CAT DrägerSensor
Menu
Default setting
A1 Alarm
2.0 % LEL
A2 Alarm
4.0 % LEL
Factory default settings
Range
0 to A1
0 to A2
0 to 720
)
0 to 25 Vol% (O
2
2
LS)
0 to 100 Vol% O
2
)
0 to -0.75 Vol%
2
)
0 to 0.75 Vol%
2
,
5 to 25 Vol% (O
2
2
LS)
5 to 100 Vol% O
2
®
DQ
Range
1 to 100 %LEL
0 to A1
0 to A2
0 to 360
-5 to 4 %LEL
-5 to 0 %LEL
0 to 4 %LEL
Range is not
adjustable
®
LC
Range
0.1 to 10 % LEL
en
)
)