Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 175
position the template correctly, checking that
the hole in the ultrasonic sensor support is
aligned with the calibration template (see figure
31) and repeat the procedure.
- the internal sensor was not in the rest position.
Position it to the rest position and repeat the
procedure.
Select the Exit
gramme without performing a calibration.
Service
This program displays some data that are used to
test machine operation and to detect the malfun-
ctioning of some devices. Since these data are not
useful for the operator, it is recommended that
only technical support technicians consult them.
Select the service programmes icon to display
this programme
Monitor Auto Setting
This program is used to optimise the synchro-
nisation of the LCD motor approved by the
manufacturer. Proceed as follows to perform this
synchronisation:
- select the
MONITOR AUTO SETTING
icon;
- once selected, the following screen will appear
on the monitor
EM 9580 Plus - EM 9580 C Plus - Operator's manual
31
icon to exit the pro-
.
- to perform the synchronisation, press the corre-
sponding key directly on the LCD monitor (read
the instructions in the monitor user manual).
Push the
exit key to exit the program
without performing the synchronisation.
IMPORTANT:
repeat the operation if necessary if the synchro-
nisation was not successful.

ERROR MESSAGES

The machine can recognise a certain number
of malfunction conditions and signals them by
displaying the relevant messages.
– A – Notice messages
A 3
Wheel not suitable for performing the sensitivity
calibration, use a wheel of average dimensions
(typically 5.5"X14") or larger but with a weight
that does not exceed 40 kg.
A 5
Incorrect wheel data for an ALU programme.
Correct the set dimensions.
A 7
The machine is temporarily not enabled to select
the programme requested.
Perform a wheel spin, then repeat the request.
A 20
Ultrasonic sensor calibration template in an
incorrect position during calibration. Bring it to
the position indicated and repeat the calibration.
A 23
Data entry incomplete or incorrect in ALU P.
Enter again correctly.
UK
81
Tabla de contenido
loading

Este manual también es adecuado para:

Laserline em 9580 c plus

Tabla de contenido