Device Disablement
In the previous version of FC520 Control panel it was
possible to see the status of devices by another FC520
Control panel in the same RS485 network.
With the current version you can also have the possibi-
lity to disable the devices belonging to a Control panel
by other Control panel placed on the same RS485 net-
work.
Use the 2 key to select "FC Device"; in the following di-
splay (Fig. 67a) it is possible to select the control panel
"Choose the panel" belongs to the device to disabled.
in this phase:
Alphanumeric keypad No function is related to
Alphanumeric keypad.
Cursor Keys No function is related to UP and Down
keys;
use the Right key to select the next available control
panel;
use the Left key to select the previous available control
panel;
ESC key Use ESC key to cancel the operation and to
step back to previous page.
ENTER key Use ENTER key to confirm and to active
the selected page.
Choosing the contro panel the next steps are shown in
Figure No. 67a.
Control panel name
Access Level
Master control panel
Choose Panel
[ MS ]
S1
S2
Abbr. of the selected
Control Panel
Figure 67a Disabling Display of devices belonging to
a loop of control Panel from another Panel
54
the symbol shows the presence
Control Panel status
of the connection between the
User interface and the main board
lev.2 :
DISABLE
Master control Panel
Name of the selected
Control Panel
Analogue Fire Panels
Key 3 -Dis. SW zone
Use the 3 key to select "Dis.SW zone"; after the zone has
been selected the zone can be disabled (see Figure 67).
n Select SW zone
(in this phase):
Alphanumeric keypad Use the Alphanumeric keypad
to select the Zone identification number.
Cursor Keys No function is related to UP, Down,
Right, Left Key;
ESC Key Use ESC key to cancel the operation and to
step back to previous page.
ENTER Key Use ENTER key to confirm and disable
the SW zone.
Function Keys No function is related to F1 key;
No function is related to F2 key;
Use the F3 key to cancel the numbers, if mistaken, in-
sert the new number;
No function is related to F4 Key.
n Dis. SW zone (in this phase):
Alphanumeric keypad No function is related to
Alphanumeric keypad.
Cursor Keys No function is related to UP, Down,
Right, Left Key;
ESC Key Use ESC key to cancel the operation and to
step back to previous page.
ENTER Key Use ENTER Key to confirm.
Function Keys No function is related to F1, F2, F3, F4
key.
Control Panel name
Access Level
Master Panel
SW zone: 097
SW zone name
Index of the zone
to view
SW zone
Control Panel name
Access Level
to disable
Master Panel
SW zone: 097
ENABLED
Disable it?
Present Status
Request to Enable/Disable
Figure 67 Display "Dis. SW. Zones "
This symbol shows the
presence of the connection
Control panel
between the User Interface
Status
and the Main Board
lev.2: DISABLE
Control panel
Status
lev.2: DISABLE
FC500