Pre-Defined Programs; Special Programs - DENTSPLY Multimat Easy Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

10 Pre-defined programs
Note: The parameters listed here have the nature of
recommendations. If necessary, conduct your own test
fi rings and adapt the parameters to your own needs. Note
that the cooling stages must be defi ned as per the alloy
manufacturers' recommendations.
Base temperature, pre-heating temperature, tempering
temperature: in °C, Pre-drying, drying, pre-heating time,
holding time, vacuum time, tempering time: in mm:ss,
Heating rate: in °C/min, Vacuum: in hPa, Cooling stage:
indicated by an asterisk (*)
Ceramco3
93
Paste opaque
94
Powder opaque
95
Shoulder
Opaque dentine,
96
dentine, effects,
enamel
Glaze firing
97
without glaze
Glaze firing
98
with glaze
Correction,
99
Add-on

Special programs

91
Heating program
92
Cleaning program
60
MultimatEasy
500
100
975
650
70
970
650
70
965
650
45
930
650
45
920
650
55
925
650
55
920
450
55
980
575
55
1200
05:00
03:00
50
03:00
03:00
50
05:00
05:00
50
05:00
05:00
50
03:00
03:00
0
03:00
03:00
0
05:00
05:00
50
03:00
02:00
50
03:00
02:00
50
00:01
00:01
00:01
00:01
00:01
00:01
00:01
01:00
00:00
00:30
00:00
00:30
00:01
00:01
05:00
05:00
09:00
10:00
Tabla de contenido
loading