ENG
3.5
Installing the ceiling arm
WARNING
The opening spring balanced arm is an injury hazard
Do not remove the transport safeguard until after the
luminaire head has been mounted
Connect the plug from the ceiling tube with plug on the
ceiling arm
Carefully push protruding cable into the ceiling tube
Perform this assembly step on an even surface:
3
Insert the sliding piece 1 above into the ceiling arm
groove 2
Push the ceiling tube 3 and ceiling arm 2 together
Secure the sliding piece 1 by screwing in the threaded
stud 4 (up to the stop)
Loosen the threaded stud 4 again by a maximum of a ¼
turn and checking the rotating function.
Continue with luminaire head assembly, see Chap. 6
4.
INSTALLATION: Triango 100 W
4.1
Workload data
Bending moment M
B
Vertical weight F
G
24
1
4
2
275 Nm
155 N
4.2. Installing the wall holder
►
Fastening hardware does not come with delivery.
DANGER
Assembly by qualified personnel
►
Assembly must be done by qualified personnel only.
Lack of appropriate knowledge may pose a death
hazard.
►
Two people are needed for assembly.
CAUTION
Determine the fasteners to use from the workload data
table
►
Before assembly, make sure the rod dimensions are
correct.
CAUTION
Make sure the wall holder is in the correct position.
►
The wall holder must be aligned according to the axis
in the image.
►
Misalignment will compromise mechanical safety.
►
We recommend using a counterplate on lightweight
construction walls (not included with delivery).
DANGER
Death hazard from electric shock.
►
All poles of the luminaire must be disconnected from
the power supply by an external lockable switch.
►
Draw 6 drill marks.
Observe the position of opening "A" for connecting
►
the current.
WARNING
Wear safety equipment according to the tool manufacturer's
instructions.
A