1.4 Technical data
1.4.1 Compressor
Rated voltage:
230 V ~ 50 Hz
Rated power:
1500 W
Mode of operation:
S3 25%*
Highest speed of the compressor: 4000 min
Pressure vessel volume: 50 l
Permissible maximum pressure: max. 10 bar
Theo. Suction capacity approx. 240 l/min
Theo. Output approx. 140 l/min
IP30
Protection class: IP30**
Dimensions: 330 x 310 x 1060 mm
Total mass (without cable and accessories): 23,8 kg
*
This means that the compressor may be operated for 2.5 minutes within
a 10- minute period and must cool down again for the remaining 7.5
minutes (at an ambient temperature of 20°C).
** IP3X: Protection against ingress of foreign bodies Ø > 2.5 mm.
Keep tools and wires away.
IPX0: No protection from water, i.e. the device must not be used in damp
or wet spaces or in the rain.
1.4.2 Spiral hose
Max. Working pressure:
10 bar (at 23 °C)
6.5 bar (at 50 °C)
Hose type:
middle area of application
Hose outer diameter:
Ø 8.0 mm
Hose inner diameter:
Ø 5.0 mm
Wall thickness:
1.5 mm
Coupling:
DN 7.2/6 mm
Connection:
¼" (6.35 mm)
Length:
5 m
Applicable
temperature range:
-10 °C to + 50 °C
1.4.3 Pneumatic tyre inflation gauge
Working pressure:
max. 8 bar
Compressed air quality:
cleaned, oil-free and condensate-free
Volume flow:
40-70 l/min
NAMEPLATE
-1
BADGE
a
c
a) maximum operating pressure (hp in bar);
b) maximum operating temperature (Tmax in °C);
c) minimum operating temperature (Tmin in °C);
d) capacity of the vessel (V in L);
e) name, registered trade name or registered trademark and address of the
manufacturer;
f) type identification and serial or batch identification of the vessel.
Explanations of all symbols found on the product
WARNING!
IP30
PVKO 50 C3
Vertikaler Kompressor 50 L
Vertical Compressor 50L
Compresseur vertical 50 l
230 V ~ , 50Hz, 1500W (S3 25%)
4000 min
-1
max. 10 bar
23,8 kg
IP30
ROWI Germany GmbH
Manufactured: 10/2023
Werner-von-Siemens-Str. 27
IAN: 435338_2304
76694 Forst | Germany
S./N.:
b
e
WARNING
Read the manual before use.
Manual must be read.
Do not expose the machine to rain. The device may
only be stationed, stored and operated under dry
ambient conditions.
Risk of high temperatures
Compressor unit may start without warning.
Protection class
WEEE
d
f
GB/IE/NI/CY/MT