To Disconnect
the 20 lb LP Gas Fuel Tank:
1. Check that the burner control knobs are in the "Off" position
and the grill is cool.
2. Check that the 20 Ib LP gas fuel tank is in the "Off" position. If
not, turn the valve clockwise until it stops.
3. Using your hand, turn the gas pressure regulator/hose
assembly counterclockwise
to disconnect
to the 20 Ib LP gas fuel
tank as shown.
Hand loosen only. Use of a wrench could damage the quick
coupling nut.
\\\
\
A. Gas pressure regulator/hose
assembly
B. 20 Ib LP gas fuel tank
GAS CONVERSION
Gather the required tools and parts before starting installation.
Read and follow the instructions
provided with any tools
listed here.
Tools needed
• Phillips screwdriver
• Pipe wrench
•Adjustable
wrench
• 6 mm socket and wrench
or 6 mm nut driver
•Thin flat-blade screwdriver
•Pliers
• Pipe thread sealant
certified for LP Gas
Parts supplied
• Natural gas orifices
Parts needed
• Natural gas conversion
kit Part Number
710-0003.
See
• "Assistance"
section to order. The conversion kit includes:
• Natural gas regulator 4" W.C. (marked "Natural Gas
•Regulator")
• 10 ft (3.0 m) Natural gas hose with quick connector
• 5.9" (150 mm) Natural gas regulator hose
• 6 mm nut driver
• 6 mm wrench
• Hex key
IMPORTANT:
Gas conversions
must be done by a qualified
installer. Before proceeding
with conversion, shut off the gas supply
to the appliance prior to disconnecting
the electrical power.
4. Place dust cap on cylinder valve outlet whenever the cylinder is
not in use. Only install the type of dust cap on the valve outlet that
is provided with the cylinder valve. Other types of caps or plugs
may result in leakage of propane.
5. Go to "Check and Adjust the Burners" section.
1"7