• Secure the pump assembly to the base whilst relieving any
leverage from the discharge hose. If you do not, the joint may
not seal.
• Examine all hoses throughout their length for chafe, kinks and
splits under hose clamps. Check all hose clamps for corrosion
and replace worn or damaged parts.
• Reconnect all loose hose ends and secure them with their
hose clamps.
• Ensure that the base drain plug (key 8) is securely in place.
CAUTION: Do NOT lubricate top or bottom valve
gaskets. Do NOT apply sealing compounds to any
gaskets or hose connections.
Trouble Shooting
Bowl fills when toilet not in use
Waste water re-appears in bowl
Bowl does not empty & difficult to push handle down
Bowl does not empty and difficult to pull handle up
Bowl does not empty although handle is easy to push & pull
Water does not come in and handle springs up if pushed
down
Water does not come in although handle is easy to push
and pull
Flush water is slow to appear during pumping
DIMENSIONAL DRAWING
Millimetres (Inches)
DESSIN DIMENSIONNEL Millimètres (Pouces) / MAßZEICHNUNG Millime-
ter (Zoll) / DISEGNO DIMENSIONALE millimetri (pollici) /
MAATTEKENING Millimeter (Inch) / DIMENSIONELL RITNING millimeter
(tum) / DIBUJO DIMENSIONAL milímetros (pulgadas)
Model No.
Description
Manual toilet compact
29090-5000
bowl
Manual toilet regular
29120-5000
bowl
• Shut Seacocks.
• Fit Vented Loops.
• Check bottom valve gasket (16) and joker valve (33).
• Open outlet seacock.
• Fully shut flush control lever (23).
• Check joker valve (33), discharge hose or outlet seacock for blockage.
• Remove pump and check for blockage.
• Check piston o-ring (30), bottom valve gasket (16) & joker valve (33).
• Open inlet seacock.
• Fully open flush control lever (23)
• Open flush control lever (23)
• Check top valve gasket (21) and piston o-ring (30)
• Check inlet hose connections are airtight
• Shorten inlet hose from main seacock
• Do not fit a vented loop between inlet seacock & pump
• Fit between pump & bowl
• Fit non-return valve (29295-1011) next to inlet seacock
Net Weight
A
9.5 kg
330
618
(21 lb)
(13)
(24.3)
10.9 kg
345
700
(24 lb)
(13.58)
(27.56)
5. Servicing - Testing
REFER to the OPERATING INSTRUCTIONS and follow the procedure
for "2. Normal use".
• If the flushing pump is hard to prime, half-fill the bowl with
fresh water.
ON COMPLETION OF SERVICING:
• SHUT
THE FLUSH CONTROL
• CLOSE BOTH SEACOCKS.
CAUTION: This toilet is designed for raw water
only. Do not connect this toilet to the boats
pressurized fresh water system.
B
C
D
247
425
(9.72)
(16.23)
280
485
(11.02)
(19.09)
8
E
F
G
485
455
168
(19.09)
(17.91)
(6.61)
580
470
183
(22.83)
(18.50)
(7.20)
mm
(in)
mm
(in)