PROBLEM
After having switched the general button on the electric pack, the general warning light does not light on and no control can func-
tion.
CAUSES
1) The power plug is not inserted.
2) No power from the mains electric supply.
REMEDIES
1) Insert the plug correctly in its socket.
2) Reset the mains electric supply.
PROBLEM
After having switched the general button on the general warning light also switches on but the motor on the hydraulic power pack
does not function.
CAUSES
1) The magneto-thermic switch for motor protection is working.
REMEDIES
1) Call for technical aid to see what is the problem and restore the machine.
PROBLEM
The manometer (21,Fig. A) reads a pressure value below 130 bar ± 5%.
CAUSES
1) The oil in the power pack is below minimum level.
REMEDIES
1) Read the paragraph "MAINTENANCE" to add oil.
PROBLEM
There is a slowing down at an the tyre changer's movements.
CAUSES
1) The oil in the power pack is below minimum level.
REMEDIES
1) Read the paragraph "MAINTENANCE" to add oil.
WARNING: If, inpite of the above mentioned indications the tyre changer does not work properly, do not use it
and contact your nearest NUSSBAUM technical assistance centre.