WARNING! Incorrect settings can result in damage to property and injury to
people and animals.
- Cut off power to the board (Fig.S ref.1)
- Open the Stop input and press the - and OK keys together (Fig.S ref.2)
- Switch on the board's power (Fig.S ref.3)
- The display will read RST; confirm within 3 sec. by pressing the OK key (Fig.S ref.4)
- Wait for the procedure to finish (Fig.S ref.5)
- Procedure finished (Fig.S ref.6)
WARNING! Incorrect settings can result in damage to property and injury to people
and animals.
WARNING: Check that the force of impact measured at the points
provided for by standard EN 12445 is lower than the value laid down
by standard EN 12453.
Impact forces can be reduced by using deformable edges.
For best results, it is advisable to run the autoset function with the motors idle (i.e.
not overheated by a considerable number of consecutive operations).
Terminal
Definition
L
LINE
Single-phase power supply 220-230V 50/60 Hz*
N
NEUTRAL
1
MOT1 +
Connection motor 1
2
MOT1 -
3
SWO 1
Motor 1 opening limit switch SWO1 (N.C.).
4
SWC 1
Motor 1 closing limit switch SWC1 (N.C.).
5
+ REF SWE
Limit switch common
6
Board power supply:
TRANSF SEC
24V~ Transformer secondary winding
7
24V= Buffer battery power supply
8
24 Vsafe-
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output active only during operating cycle.
9
24 Vsafe+
10
24V-
Accessories power supply output.
11
24V+
AUX 0 - 24V
12
POWERED
AUX 0 configurable output - Default setting FLASHING LIGHT.
CONTACT
2ND RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR LIGHT/ GATE OPEN ALARM/ FLASHING
13
(N.O.) (MAX.
LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK. Refer to "AUX output configuration" table.
1A)
14
MOT2 +
Connection motor 2
15
MOT2 -
16
SWO 2
Motor 2 opening limit switch SWO2 (N.C.).
17
SWC 2
Motor 2 closing limit switch SWC2 (N.C.).
18
+ REF SWE
Limit switch common
Configurable command input 2 (N.O.) - Default PED.
19
IC 2
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
20
FAULT 1
Test input for safety devices connected to SAFE 1.
Configurable safety input 1 (N.C.) - Default PHOT.
21
SAFE 1
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST
Refer to the "Safety input configuration" table.
The command stops movement. (N.C.)
22
STOP
If not used, leave jumper inserted.
Configurable command input 1 (N.O.) - Default START E.
23
IC 1
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
24
Common
IC 1 and IC 2 inputs common
25
Not used
26
Not used
27
SHIELD
Antenna input.
Use an antenna tuned to 433MHz. Use RG58 coax cable to connect the Antenna and Receiver. Metal bodies close to the antenna can interfere with
28
ANTENNA
radio reception. If the transmitter's range is limited, move the antenna to a more suitable position.