x 2
***
0---
10--
ALT
follow the user guide
add. start
Add. 2ch
erase 64
language
autoset
Control unit
software version
stat
vers
OK
No total
- +
manoeuvres(in hundreds)
n. cycles
OK
- +
No radio control
devices memorised
n. remotes
OK
- +
List of last 30 errors
err
OK
0---
password
30
- VIRGO
ACCESS MENUS Fig. 1
INSTALLATION MANUAL
150-
1520
See PARAMETERS MENU
See LOGIC MENU
hidden butt
release
desired button
hidden butt
release
desired button
See RADIO MENU
Diagnostics
code
STRE
STRI
OPEN
CLS
PED
TIME
STOP
PHOT
PHOP
PHCL
bft . . .
SWC1
+/-
SWO1
0000
+/-
SWC2
00
SWO2
+/-
01.33
SET
02.01
ER01
........
ER03
30.15
+/-
ER04
ER1x*
ER3x*
ER4x*
ER7x*
10--
150-
ok
DESCRIPTION
START E external start input activated
START I internal start input activated
OPEN input activated
CLOSE input activated
PED pedestrian input activated
TIMER input activated
STOP input activated
Activation of PHOT photocell input or, if
configured as verified photocell, Activation
of the associated FAULT input
Activation of PHOT OP opening photocell
input or, if configured as active verified pho-
tocell only when opening, Activation of the
associated FAULT input
Activation of PHOT CL closing photocell input
or, if configured as active verified photocell
only when closing, Activation of the associa-
ted FAULT input
SWC1 motor 1 closing limit switch input
activated
SWO1 motor 1 opening limit switch input
activated
SWC2 motor 2 closing limit switch input
activated
SWO2 motor 2 opening limit switch input
activated
The board is standing by to perform a
complete opening-closing cycle uninter-
rupted by intermediate stops in order to
acquire the torque required for movement.
WARNING! Obstacle detection not active
Photocell test failed
Opening photocell test failed
Closing photocell test failed
Board hardware test error
Reverse due to obstacle - Amperostop
Thermal cutout
Internal system supervision control error.
*X= 0, 1, .., 9, A, B, C, D, E, F
1520
*** Password entry.
Request with Protection Level
logic set to 1, 2, 3, 4
Scroll up
Scroll down
Con rm/Switch on display
Exit Menù
35. 4 0
Instantaneous force motor 2
Instantaneous force motor 1
NOTES
Check photocell connection and/or logic settings
Check photocell connection and/or parameter/
logic setting
Check photocell connection and/or parameter/
logic setting
- Check connections to motor
- Hardware problems with board (contact techni-
cal assistance)
Check fo r obstacles in path
Allow automated device to cool
Try switching the board off and back on again. If the
problem persists, contact the technical assistance
department.
prg