Technical data
10.1 Overall system
Flow rate of respiratory pro-
tective device/helmet/visor:
Flow rate of half/full face
mask:
Rated period of service:
1)2)
Operating temperature
Operating and storage area
1)
humidity
1)
Storage temperature
Noise:
International Protection Code IP 65
1) Battery charger and rechargeable batteries, see separate information
in this chapter. Other components, see corresponding instructions for
use.
2) For X-plore 8700 -10 °C to +50 °C.
RFID
Technology
Frequency range
Broadcast transmission
capacity
Bluetooth
Technology
Frequency range
Broadcast transmission
capacity
Instructions for use
|
Dräger X-plore
170/190/210 L/min
115/130/145 L/min
4 hours with standard
rechargeable battery
8 hours with long-life
rechargeable battery
-10 °C to +60 °C
≤ 95 % relative humidity
-20 °C to +60 °C
approx. 64 dB(A)
Induction transfer
13553 to 13567kHz
-2.30 dBµA/m (10 m)
FHSS 2.4 GHz (BT 2.1 +
EDR)
2402.0 to 2483.5 MHz
0.97 mW / -0.14 dBm EIRP
®
8000
10.2 Rechargeable batteries
1)
Operating temperature
Operating and storage area
humidity
Storage temperature
Charging temperature
1) For rechargeable batteries for X-plore 8700 in explosion-hazard areas
-10 °C to +50 °C.
Standard rechargeable battery
Charging time:
Operational life time after a
full charge
Rated voltage
Rated capacity:
Stored energy
1) Varies depending on the preset flow rate and the filter and facepiece
type used.
Long-life rechargeable battery
Charging time:
Operational life time after a
full charge
Rated voltage
Rated capacity:
Stored energy
1) Varies depending on the preset flow rate and the filter and facepiece
type used.
10.3 Standard battery charger
Input voltage
Input current
Output voltage
Output current
International Protection Code IP 30
Operating temperature
Operating/storage area
humidity:
Storage temperature
|
Disposal
-10 °C to +60 °C
≤ 95 % relative humidity
-20 °C to +50 °C
0 °C bis +50 °C
< 4 hours
1)
approx. 4 hours
10.8 V
3.35 Ah
36 Wh
< 4 hours
1)
approx. 8 hours
10.8 V
6.70 Ah
72 Wh
16 V
3.75 A
9 - 12.6 V
4 A
0 °C to +50 °C
≤ 95 % relative humidity
-20 °C to +50 °C