cecotec AIRCLIMA 9000 SMARTFRESH Manual De Instrucciones página 98

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
ENGLISH
Note that:
1. The installation site must be well ventilated.
2. Locations for installation and servicing of an air conditioner using R32 refrigerant must
be free from open fire or welding, smoke, drying oven or any other heat source greater
than 548 that readily produces open fire.
3. When installing an air conditioner, it is necessary to take appropriate anti-static
measures, such as wearing anti-static clothing and/or gloves.
4. It is necessary to choose a suitable location for installation or maintenance, the air inlets
and outlets of the indoor and outdoor units must not be surrounded by obstacles or close
to heat sources or flammable and/or explosive environments.
5. If the indoor unit leaks refrigerant during installation, the outdoor unit valve must be
closed immediately and all personnel must leave until the refrigerant drips completely
for 15 minutes. If the product is damaged, it is imperative to bring the damaged product
to the service station and it is forbidden to solder the refrigerant pipe or perform other
operations at the user's site.
6. It is necessary to choose a place where the air inlet and outlet of the indoor unit is uniform.
7. It is necessary to avoid places where there are other electrical products, power sockets,
kitchen cabinet, bed, sofa and other valuables just below the lines on both sides of the
indoor unit.
Suggested tools
Tool
Image
Standard
spanner
Wrench/
adjustable
spanner
Torque
spanner
Hex keys or
Allen keys
Drill and drill
bits
Hole saw
98
AIRCLIMA 9000 SMARTFRESH/ AIRCLIMA 12000 SMARTFRESH/ AIRCLIMA 18000 SMARTFRES/
AIRCLIMA 24000 SMARTFRESH/ AIRCLIMA 12000 SMARTFRESH CONNECTED
Tool
Image
Pipe cutters
Screwdrivers
(Phillips and
flat blade)
Manifold
and pressure
gauge
Level
Widening
tool
Clamp on
ampere
meter
Tool
Image
Vacuum
pump
Safety
goggles
Work
gloves
Refrigerant
scale
Micron
gauge
loading