cecotec AIRCLIMA 9000 SMARTFRESH Manual De Instrucciones página 104

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
ENGLISH
Step 8. Mount the indoor unit
8.1 Slowly pass the coolant pipes, connecting cables and the bundle of wrapped drain hoses
through the hole in the wall.
8.2 Hook the upper part of the indoor unit onto the mounting plate.
8.3 Apply light pressure on the left and right sides of the indoor unit, make sure that the
indoor unit is securely latched.
8.4 Push down the bottom of the indoor unit to let it hook onto the hooks of the mounting
plate, and make sure it is hooked firmly.
Sometimes, if the refrigerant pipes were already embedded in the wall, or if you want to
connect the pipes and cables in the wall, do the following:
Hook the upper part of the indoor unit onto the mounting plate without pipes and wires.
I.
II. Lift the indoor unit in front of the wall, unfold the bracket on the mounting plate and use
this bracket to prop up the indoor unit, there will be a large space for operation.
III. Make the coolant pipes, fit them, connect the drain hose, and wrap them as in steps 4 to
7.
3.3 Installation of the outdoor unit
Step 1. Select the installation site. Fig. 16
Select a site that allows the following:
1.1 Do not install the outdoor unit near sources of heat, steam or flammable gas.
1.2 Do not install the unit in very windy or dusty places.
1.3 Do not install the unit where people often pass by. Select a location where the air
discharge and operating sound will not disturb the neighbours.
1.4 Avoid installing the unit where it will be exposed to direct sunlight (otherwise, use a
shield, if necessary, which should not interfere with airflow).
1.5 Reserve the spaces as shown in the figure for free circulation.
1.6 Install the outdoor unit in a safe and solid place.
1.7 If the outdoor unit is subject to vibrations, place the rubber blankets on the feet of the unit.
Step 2. Installation of a drain hose. Fig. 17
2.1 This step is only for heating pump models.
2.2 Insert the drain gasket into the hole at the bottom of the outdoor unit.
2.3 Connect the drain hose to the joint and make the connection tightly enough.
Fig. 17 key:
Drainage joint
1.
Draining hose
2.
104
AIRCLIMA 9000 SMARTFRESH/ AIRCLIMA 12000 SMARTFRESH/ AIRCLIMA 18000 SMARTFRES/
AIRCLIMA 24000 SMARTFRESH/ AIRCLIMA 12000 SMARTFRESH CONNECTED
loading