3. Put back the stop bolt to the standard cutting mode
after the pipe cutting operation. The arrow (A) shows
the standard cutting mode.
Wet cutting
CAUTION:
together with the wet system.
•
Diamond blades for wet cutting must be used with
the wet system.
•
Water cool the blade and increases its service life
while also decrease the dust.
•
When wet cutting, make sure to collect the waste
water safely.
To decrease dust during operation
The product has a wet cutting kit to decrease harmful
dust in the air during operation. The wet cutting kit has
low water consumption.
•
When possible, use wet cutting blades with water
Diamond blades for wet cutting on
cooling. Refer to
page 18 .
•
Adjust the water flow with the valve. The correct flow
is different for different types of tasks.
•
Make sure that the water pressure is correct. Refer
Technical data on page 38 . If the water hose
to
comes off at the supply source, the supplied water
pressure can be too high.
26
A
Do not use Vac equipment
To connect the coolant water
1. Connect the water hose to the water supply (A).
A
2. Turn the water valve (B) to start or stop the water
flow.
3. Examine the water connection and the hose for
leakage.
4. Make sure that the water pressure is not higher
than the maximum permitted water pressure, refer
Technical data on page 38 .
to
Dry cutting
•
When dry cutting, lift the blade out from the cut each
30–60 seconds and let it rotate in the air for 10
seconds to let it cool.
•
Use Vac equipment if possible.
To start the product
1. Do a check of the power trigger and power trigger
To do a check of the power trigger
lockout. Refer to
lockout on page 33 .
B
1598 - 007 - 28.09.2023