Chapter 3. Correcting Errors
Display or Action
BRAKE PRESS. FAULT
THREE WIRE DISABLED
INVERTER FAULT
VIBRATION SW TRIPPED
RECOVERY SEQUENCE
PELLERIN MILNOR CORPORATION
Explanation
This error appears only on machine models equipped with a
cylinder brake. The message indicates that the brake is engaged
when it should be disengaged. This is usually because the
machine is not receiving sufficient air pressure to open the
normally-closed brake. Check the plant compressed air supply.
The three-wire relay de-energized. This relay provides control
circuit power to the machine. Once energized by momentarily
depressing the Start button (
normally open contacts, along with motor overloads, door
interlocks, etc. Should any of these contacts open even
momentarily, the machine stops and this display appears. This
error can only be cleared by depressing the Start button (
only then if the error has been cleared.
This error message appears if the microprocessor does not
receive an input from the inverter within 14 seconds of the
beginning of the formula. After 14 seconds without an inverter
input, the timer stops, the basket is stationary, and the drain
valve opens. To recover, press the Next key (
When the vibration switch closes, the timer stops. After 45 to 85
seconds (120 seconds on 42032F7J models), the basket reverses
at wash speed as the cylinder fills with water. When low level is
achieved, the cylinder reverses for one additional minute at wash
speed, then accelerates to extract speed.
— End of BICJHT04 —
14
), it is held energized by its own
\
).
y
), and
\