Dometic FreshWell FWX4350EHP Instrucciones De Montaje Y De Uso página 25

Equipo de aire acondicionado de cajón
Ocultar thumbs Ver también para FreshWell FWX4350EHP:
 
Installing the external grids
Fasten the external grids with screws and washers.
Fig. 
on page 7
Installing the receiver (optional)
1.
Drill an opening of 50 mm into the wall.
Fig. 
on page 7
2. Lay the cable through the hole to the under-bench air conditioner.
3. Fasten the receiver.
Fig. 
on page 7
Installing a control panel (optional)
The under-bench air conditioner can be connected and controlled with the CI bus of the vehicle instead of the
remote control including the receiver.
If desired, connect the under-bench air conditioner to the CI bus of the vehicle.
Note Follow the manufacturer's instructions.
Installing the temperature sensor
When installing the temperature sensor note the following:
• Install the temperature sensor in chest height.
• Install the temperature sensor on the opposite side of the air outlets in the vehicle.
• Incorrect installation of the temperature sensor may cause malfunction of the under-bench air conditioner and
poor air distribution. If the installation of the temperature sensor is incorrect, the under-bench air conditioner
will run continuously or stop working without reaching the target temperature.
1.
Drill a hole into the wall infront of the under-bench air conditioner.
Note Ensure that the hole is drilled so that the temperature sensor is not placed outside the vehicle.
Fig. 
on page 8
2. Plug the temperaturesensor into the "TA" connector (Fig. , 3) of the under-bench air conditioner.
3. Insert the sensor through the drilled hole.
4. Put the plastic cover on the temperature sensor.
Laying the connecting cables
DANGER! Electrocution hazard
Ensure that no voltage is applied to electrically operated components before carrying out any work on
them.
EN
23
loading