„ GENERAL
Your air compressor was designed for 100% continuous duty
operation with the use of All Season Select synthetic compressor
lubricant and 60% continuous duty operation with the use of
petroleum lubricant. In other words, synthetic lubricant allows
the compressor to pump continuously without cycling. Petroleum
lubricant limits the compressor to a maximum of 36 minutes of
pumping time per hour. The compressor should not cycle more than
10 times per hour.
„ NORMAL START-UP
1. Set the pressure switch lever to "OFF".
Pressure Switch Lever
2. Close the regulator by turning it fully counterclockwise (-).
Regulator
3. Attach hose and accessory.
4. Move the pressure switch lever to "ON/AUTO". The unit will start.
5. Allow tank pressure to build. The motor will stop when tank
pressure reaches cut-out pressure.
6. Adjust the regulator to the desired secondary pressure
by turning it clockwise (+) to increase the pressure or
counterclockwise (-) to decrease the pressure.
Note - When the receiver tank pressure drops below the factory pre-
set minimum, the pressure switch resets and restarts the unit.
EN-6
OPERATION
„ SHUTDOWN
1. Set the pressure switch lever to "OFF".
2. Close the service valve fully.
3. Remove the air tool or accessory.
4. Slowly open the service valve to bleed air pressure down to 20
psig.
5. Slowly open the manual drain valve at the bottom of the tank
to drain all condensate (water).
6. Close the drain valve and the service valve for the next use.
7. Wrap the power cord firmly around the handle.
8. Store the unit indoors.
9.
80444425 Rev. D