Stahlwille SENSOTORK 712R/6 Manual De Instrucciones página 37

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 76
EN
Input of data for a tightening define
process
Shown below are the operating steps necessary for
the practical example.
DANGER
Danger of severe or fatal injuries due to
take-over of incorrect measured values.
The data and values in the following
example are not guideline values.
 Never use example values for a working
process.
Switching on
 To switch the torque wrench on, press any button.
Both light emitting diodes light up while the torque
wrench is booting. The serial number and the software
version then appear on the display.
 Activate the operating software with the "MR"
button.
The wrench is now ready for operation and is in the
"Track/dial mode".
Input of adjusting parameters
 To call-up the menu, press the "ML" button
 Enter the administrator's password.
 Confirm with the "MR" button.
 If no administrator's password has been set,
confirm without further input by means of the "MR"
button.
You are now in the menu and the first menu item
"adjusting operations" is already selected.
 To enter the "adjusting operations" sub-menu,
press the button "MR".
In the "adjusting operations" menu
new operations can be drawn up,
You can edit bolting operations (change and
delete).
 Select the item "new adjusting parameters".
 Confirm with the button "MR ".
In order to process the settings for adjusting
parameters, select items from the following list of
parameters:
Mode (only SENSOTORK
Torque or angular starting torque and angle
®
(SENSOTORK
713R only)
Tolerance
Pre-warning
Adaptor length
Measurement unit
Name
The parameters for the first adjusting parameters can
be entered as follows:
 To select "Mode", press the "MR" button.
12
®
713R
 To set the operating mode, select the item "Angle"
from the list, using the "O" or "U" buttons.
 Confirm the selection with the "MR" button.
You are back in the list of parameters on the list item
"Mode".
 To select the "Angular starting torque" menu item,
press the "U" button.
 To set an input for the angular starting torque,
press the "MR" button.
The previous value for the angular starting torque is
shown on the display. To enter the value 10, for
example, proceed as follows:
 Press the "L" button three times in quick
succession.
The cursor now flashes below the number to be set.
 Press the "O" or "U" button until a "1" is displayed
above the cursor.
 To position the cursor beneath the ones digit,
press the "R" button once.
 Now press the "O" or "U" button until a "0" is
displayed.
The value "10" for the angular starting torque is shown
on the display.
 Confirm the input with the "MR" button.
You can select the next list entry from the parameter
list.
 To select the "Angle" entry, press the "U" button.
 To carry out an input, press the "MR" button.
To enter the value 25 degrees, for example, proceed
as follows:
 Press the "L" button three times in quick
succession.
The cursor now flashes below the number set for the
tens digit.
 Press the "O" or "U" button until a "2" is displayed.
 To position the cursor beneath the ones digit,
press the "R" button once.
 Now press the "O" or "U" button until a "5" is
displayed.
The value "25" for the angle is shown on the display.
 Confirm the input with the "MR" button.
The next item can be selected from the list of
parameters.
Enter in the same manner the imaginary values for:
Tolerance (5.6),
Pre-warning [%] (60),
Adaptor length (remains unchanged for now) and
unit (N·m).
ATTENTION
Settings for the bolting type are not stored.
 Always complete the input of a bolting type by
assigning a name.
 To store all settings for a adjusting parameters,
the operation must receive a name.
 Select the menu item "Name".
loading

Este manual también es adecuado para:

Sensotork 713r