Product overview
The figure shows an Air Guard 6700 HP.
Pos. Description
1
Gas outlets
2
Touchscreen with the keys F1 to F4 and a USB port on
the rear side for the data logger
20
Pos. Description
3
Signal lamps
Red: Alarm A2
Yellow: Warning A1
Green: Ready for operation
1
4
Alarm horn
5
High or medium pressure input depending on the
specification
6
Polytron 7000, the right-hand Polytron 7000 is optional
7
Differential pressure sensor
8
PIR 7200
2
9
PID 5000
10
Moisture sensor
3
11
Solenoid valve for purging
4
12
Pressure reducer (only in HP variants)
13
Circuit breaker
5
14
Measuring gas moisturisation
3.2
Feature description
The Air Guard continuously monitors the connected breathing
air supply in accordance with the thresholds in the
DIN EN 12021 standard. For continuous monitoring, it is
necessary for the Air Guard to be permanently supplied with
breathing air.
If it is not possible to continuously apply breathing air to the
Air Guard, either the "Intelligent purging" feature (see below for
6
the requirements) must be used or, in the case of Air Guards
which do not meet the requirements, the Air Guard must be
permanently supplied with compressed air or switched off. The
PID 5000 may be damaged if this is not observed.
The requirements for using intelligent purging are:
Air Guard software version, PLC 2.6 and HMI 2.3 or higher
(see chapter 4.4.7)
7
PID 5000 serial number 56922xxxxx or higher
8
Alarms are issued when limits are exceeded. The alarms are
9
transmitted to signal lamps at the front of the device. There are
10
additional potential-free contacts available, for example, to
give feedback on compressor control or the filling panel.
11
12
The Air Guard has 4 base models, each of which can be
equipped with the external visual warning option (additional
13
signal lamp). The base models are:
Air Guard 6500 HP
Air Guard 6500 LP
Air Guard 6700 HP
Air Guard 6700 LP
6500
Measurement of CO, CO
14
oil content
6700
Measurement of CO, CO
oil content as well as H
LP
Maximum operating pressure: 6-10 bar
HP
Maximum operating pressure: 200-330 bar
, O
, moisture and residual
2
2
, O
, moisture and residual
2
2
S (hydrogen sulphide)
2