Operation
32
If two signals for the speed setting are present at the same
time: at pin 5 as PWM signal and at pin 1 as analog signal,
the PWM signal is taken as the setpoint and the analog signal
is ignored.
7.4.3 Digital setpoint setting
Interface configuration
Designation
Baud rate
Data bits
Parity
Stop bits
Flow control
Tab.14: Settings of the UART interface
Interface protocol
Tables Tab. 15 [} 33] to Tab. 16 [} 34] contain the com-
mand sets necessary for the interface protocol, expressed as
ASCII characters. Each of the commands is to be terminated
with the ASCII character <CR> (carriage return, decimal value
013). The underlined expressions are not characters but
rather symbols. The symbols are explained in Tab. 16
[} 34].
There must be a pause of 25 ms between each UART com-
mand and the next command.
The symbols represent the ASCII code of numerical se-
quences of any length. Input values are only processed by the
controller as whole numbers (integers).
Translation of Original Operating and Installation Instruction, KNF
Diaphragm pump N952KTE-W N952KT.29E-W
Value
57600 bits/s
8
none
1
none
339866-336533 02/23